2PX/2PY
1-5-3
1-5-2 Outer covers
(1) Detaching and refitting the rear upper cover, right upper cover, left upper cover
and front cover
Procedure
1. Open the paper conveying unit.
2. Release the hook and then remove the
IF cover.
Figure 1-5-3
3. Remove two screws and then remove
the rear upper cover.
Figure 1-5-4
IF cover
Paper
conveying
unit
Hook
Rear upper cover
Screw
Screw