2PX/2PY-1
1-5-73
56. Remove the FFC wire connecting to the
ISU from the wire alignment part in the
scanner unit.
Take off the bending part of the FFC
wire from the two double-sided tapes on
the wire alignment part.
Detach the ISU.
Then, peel off the double-sided tapes
and clean the affixing part to remove
the adhesive.
Figure 1-5-118
Double-sided
tape
ISU
FFC wire