FS-9120DN/9520DN
1-5-4
Section Jam code Description Conditions
Fixing sec-
tion
Eject sec-
tion
Feedshift
section
Optional
switchback
unit
41
42
43
44
46
47
50
52
53
Misfeed in fixing section
(upper cassette)
Misfeed in fixing section
(lower cassette)
Misfeed in fixing section
(paper feeder PF-70* up-
per cassette)
Misfeed in fixing section
(paper feeder PF-70*
lower cassette)
Misfeed in fixing section
(paper feeder PF-75*)
Misfeed in fixing section
(duplex section)
Misfeed in eject section
Misfeed in feedshift sec-
tion
Misfeed in switchback
section
The eject switch (ESW) does not turn on within a specified
time of the registration clutch (RCL) turning on.
The feedshift switch (FSSW) does not turn on within a speci-
fied time of the registration clutch (RCL) turning on.
The eject switch (ESW) does not turn on within a specified
time of the registration clutch (RCL) turning on.
The feedshift switch (FSSW) does not turn on within a speci-
fied time of the registration clutch (RCL) turning on.
The eject switch (ESW) does not turn on within a specified
time of the registration clutch (RCL) turning on.
The feedshift switch (FSSW) does not turn on within a speci-
fied time of the registration clutch (RCL) turning on.
The eject switch (ESW) does not turn on within a specified
time of the registration clutch (RCL) turning on.
The feedshift switch (FSSW) does not turn on within a speci-
fied time of the registration clutch (RCL) turning on.
The eject switch (ESW) does not turn on within a specified
time of the registration clutch (RCL) turning on.
The feedshift switch (FSSW) does not turn on within a speci-
fied time of the registration clutch (RCL) turning on.
The eject switch (ESW) does not turn on within a specified
time of the registration clutch (RCL) turning on.
The feedshift switch (FSSW) does not turn on within a speci-
fied time of the registration clutch (RCL) turning on.
The eject switch (ESW) does not turn off within a specified
time of the registration switch (RSW) turning off.
The eject switch (ESW) does not turn off within a specified
time of the registration clutch (RCL) turning on.
The feedshift switch (FSSW) does not turn on within a speci-
fied time of the start of eject motor (EM) reverse rotation.
During paper switchback operation, the feedshift switch
(FSSW) does not turn off within a specified time of the
feedshift switch (FSSW) turning on.
The feedshift switch (FSSW) does not turn off within a speci-
fied time of the registration switch (RSW) turning off.
The feedshift switch (FSSW) does not turn off within a speci-
fied time of the registration clutch (RCL) turning on.
The switchback eject switch (SBESW) does not turn off
within a specified time of the feedshift switch (FSSW) turn-
ing on.
The switchback eject switch (SBESW) does not turn on
within a specified time of the feedshift switch (FSSW) turn-
ing on.
The switchback eject switch (SBESW) does not turn off
within a specified time of the feedshift switch (FSSW) turn-
ing off.
*Optional.