1-5-22
Code Contents
Remarks
Causes Check procedures/corrective measures
FS-9120DN/9520DN
6050
6400
6410
6420
7300
Abnormally low fuser unit thermistor
temperature
When only fuser heater M is on, fuser
unit thermistor 2 detects temperature
lower than 80 °C/176 °F during print-
ing.
•When fuser heater M and fuser unit
heater S are on, fuser unit thermistor
2 detects temperature lower than 80
°C/176 °F or fuser unit thermistor 1
detects temperature lower than 100
°C/212 °F during ptinting.
Zero-crossing signal problem
The engine controller PWB does not
detect the zero-crossing signal (Z
CROSS SIG) for the time specified
below.
At power-on: 5 s
Others: 5 s
Fuser unit connector insertion prob-
lem
Absence of the fuser unit is detected.
Fuser unit fuse cut problem
•When you try to cut the fuser fuse,
the fuse is not cut even after 3 s
elapse.
Toner sensor problem
While the toner container sensor is
on, the toner sensor in the developing
unit does not turn on after the toner
sensor turns off and toner is replen-
ished from the toner container.
Broken fuser
heater M or S
wire.
Poor contact in
the connector ter-
minals.
Defective power
supply unit.
Defective engine
controller PWB.
Fuser unit con-
nector inserted
incorrectly.
Defective fuser
unit connector.
Poor contact in
the connector ter-
minals.
Fuser unit con-
nector inserted
incorrectly.
Defective toner
sensor.
Poor contact in
the toner sensor
connector termi-
nals.
Defective toner
container sensor.
Defective toner
container.
Check for continuity. If none, replace the
fuser heater M or S (see page 1-6-20).
Check the connection of connectors YC1-3
on the engine controller PWB and YC2-6
on the power supply unit, and the continu-
ity across the connector terminals. Repair
or replace if necessary.
Check if the zero-crossing signal is output
from YC2-6 on the power supply unit. If
not, replace the power supply unit.
Replace the engine controller PWB if
C6400 is detected while YC2-6 on the
power supply unit outputs the zero-cross-
ing signal.
Reinsert the fuser unit connector if neces-
sary.
Replace the fuser unit.
Check the connection of connector YC10
on the engine controller PWB and the con-
tinuity across the connector terminals. Re-
pair or replace if necessary.
Reinsert the fuser unit connector if neces-
sary.
Replace the toner sensor.
Reinsert the connector. Also check for con-
tinuity within the connector cable. If none,
remedy or replace the cable.
Replace the toner container sensor.
Replace the toner container.