— 14 —
2. Features
This instrument, 1009, is a Digital Multimeter which designed for making measurement of the low-voltage equipment.
(1) Designed to international safety standards. (6) Auto-ranging function
IEC 61010-1, IEC61010-2-033 Measurement CAT. Ⅲ 300V Pollution degree 2 (7) Frequency measurement function
IEC61010-031 (Requirements for the hand-held probe) (8) DUTY measurement function
(2) REL function to check the difference of measured values (Express Pulse width / Pulse period as a percentage)
(3) Auto power off function to save battery consumption (9) Current function is protected by fuse
(4) Data hold function (
10
) Instrument is protected from mechanical shock by holster.
(5) Diode and Continuity check function
3. Specification
● Measuring ranges and accuracy (23±5℃ , under the 45%〜75%RH)
Ranges
DCV
400 mV
4V
40 V
400 V
600 V
0〜600V
(5 Autoranging)
Input impedance approx. 10MΩ
± 0.6%rdg ± 4dgt
± 1.0%rdg ± 4dgt
± 1.6%rdg ± 4dgt (50 / 60Hz)
± 2.0%rdg ± 4dgt (〜400Hz)
± 1.3%rdg ± 4dgt (50 / 60Hz)
± 1.7%rdg ± 4dgt (〜400Hz)
± 1.6%rdg ± 4dgt (50 / 60Hz)
± 2.0%rdg ± 4dgt (〜400Hz)
± 2.0%rdg ± 4dgt
± 1.0%rdg ± 4dgt
20〜399.9mV
Input impedance approx. 10MΩ
0〜600V
(4 Autoranging)
Input impedance approx. 10MΩ
0〜4000uA
(2 Autoranging)
0〜400mA
(2 Autoranging)
400 mV
4V
40 V
400 V
600 V
400 uA
4000 uA
40 mA
400 mA
ACV
DCA
Measuring range
Accuracy