— 16 —
● Operating Environmental − indoor use
conditions − altitude up to 2000m
● Temperature & Humidity range
(guaranteed accuracy) 23℃ ±5℃ Relative humidity: less than 75%
● Operating Temperature &
Humidity range 0℃〜+40℃ Relative humidity: less than 80%
● Storage Temperature &
Humidity range -20℃〜+60℃ Relative humidity: less than 70%
● Insulation Resistance It should be more than 10MΩ/DC1000V between electrical circuit and enclosures.
● Withstand Voltage It should be more than AC3470V/ for five seconds between electrical circuit and enclosures.
● Overload Protection Voltage function : 400mV range : 250V(RMS.) 10seconds
except for 400mV range
: 600V(RMS.) 10seconds
Resistance function : 250V (RMS.) 10seconds
Capacity function
: 250V (RMS.) 10seconds
Frequency function
: 250V (RMS.) 10seconds
Current function : uA, mA
: Protected by 600V0.5A fuse
A
: Protected by 600V/10A fuse
● Dimensions / Weight approx. 155(L) x 75(W) x 33(D) mm / approx. 260g(including batteries)
● Power source Two R6P(AA)1.5V or equivalent
● Accessories Test lead 1set / R6P (AA) 2p.c.s / Holster 1 /Instruction manual 1
● Fuse F 600V/500mA(fast acting type), φ6.3 x 32mm / F 600V/10A(fast acting type), φ6.3 x 32mm
CAUTION
The voltage shown above is the overload protection (overvoltage protection) for the instrument.
Make sure not to exceed the value of voltage shown above.
4. Instrument Layout
① Function Selector Switch ② Display
③ RESET Key ④ SELECT Key
⑤ RANGE Key ⑥ REL Key
⑦ HOLD Key ⑧ Hz/DUTY Key
⑨ Measuring terminal (V/Ω/Hz) ⑩ Measuring terminal (COM)
⑪ Measuring terminal (mA) ⑫ Measuring terminal (A)
⑬ Test Leads ⑭ Holster
⑮ Barrier ⑯ Cap
①
③
④
⑤
②
⑪
⑫
⑩
⑨
⑧
⑦
⑬
⑮⑮
⑯ ⑯
⑭
⑥
Barrier: provides protection against electrical shock and ensuring the minimum required air and
creepage distances.
Cap:Choose and use the test leads and caps that are suitable for the measurement category.
When the instrument and the test lead are combined and used together, whichever lower
category either of them belongs to will be applied.