max output power at 8 Ω per channel (EIA) | 350 W |
---|---|
max output power at 8 Ω per channel (FTC) | 340 W |
max output power at 4 Ω per channel (EIA) | 650 W |
max output power at 4 Ω per channel (FTC) | 630 W |
max output power at 2 Ω per channel (EIA) | 1100 W, 1175 W |
max output power at 2 Ω per channel (FTC) | 950 W |
max output power at 8 Ω bridged (EIA) | 1400 W |
max output power at 8 Ω bridged (FTC) | 1300 W |
max output power at 4 Ω bridged (EIA) | 2200 W |
max output power at 4 Ω bridged (FTC) | 1900 W |
max output voltage at 8 ohms load, MLS @ 0 dB | 53 Vrms |
---|---|
peak voltage, no load | 77 V |
slew rate | 40 V/µs |
THD 20 Hz–20 kHz and 1 W to full power | 0.03 % |
---|---|
THD @ 1 kHz and –1 dB under clip | 0.006 % |
DIM 30 at –3 dB under clip | 0.008 % |
hum and noise | <–110 dB |
channel separation @10kHz | 70 dB |
gain, selectable | 20, 23, 26, 29, 32, 35, 38, 41 dB |
---|---|
impedance | 20 kohm |
common mode rejection | 50 dB |
operation voltage (230 V version) | 130 V–265 V AC |
---|---|
operation voltage (115 V version) | 65 V–135 V AC |
minimum start voltage (230 V version) | 175 V |
minimum start voltage (115 V version) | 85 V AC |
full output power at 4 ohms (230 V version) | 180 V–265 V AC |
full output power at 4 ohms (115 V version) | 90 V–130 V AC |
peak inrush current (soft start limited) | 5 A |
quiescent power (no load) (230 V version) | 0.9 Arms |
---|---|
quiescent power (no load) (115 V version) | 1.8 Arms |
1/8 of full power (–9 dB) (230 V version) | 5 Arms |
1/8 of full power (–9 dB) (115 V version) | 10 Arms |
1/3 of full power (–5 dB) (230 V version) | 8 Arms |
1/3 of full power (–5 dB) (115 V version) | 16 Arms |
at full power (0 dB) @1 kHz 1% THD (230 V version) | 14 Arms |
at full power (0 dB) @1 kHz 1% THD (115 V version) | 28 Arms |
net dimensions (mm) | 483 W ✕ 88 H ✕ 287 D |
---|---|
net dimensions (inch) | 19˝ W ✕ 3.5˝ H ✕ 11.3˝ D |
shipping dimensions (mm) | 560 W ✕ 180 H ✕ 500 D |
shipping dimensions (inch) | 22˝ W ✕ 7.1˝ H ✕ 19.7˝ D |
net weight | 7.9 kg (17 lbs) |
shipping weight | 9.6 kg (21.2 lbs) |
Explains safety symbols like lightning and exclamation marks, and provides critical warnings.
Essential guidelines for safe operation and setup to prevent electrical hazards and damage.
Warns about amplifier power potentially damaging loudspeakers and humans, and output voltage hazards.
Combining channels for single load, impedance, and attenuator settings.
AC mains voltage, connection warnings, and primary switching capabilities.
Automatic grounding, tying signal ground, AC mains filter requirements.
Essential checks before powering on and during startup.
Prevents speaker damage from clipping and protects against overheating.
Steps to diagnose and resolve common faults like no output or protection activation.