EasyManua.ls Logo

Lagoon 52 - 3 Safety; Fire

Lagoon 52
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
3.1 . Fire
3.1.1
. Risks
3.1.2
. Fire ghting equipment
Portable extinguishers: to be provided by the
owner. The enforcement of the national regulation
under the  ag of which you are sailing is your
responsibility. The boat, when sailing, must be
tted with portable extinguishers.
We advise you to provide at least 1 extinguisher
within a 5 meter distance to each berth, within a
2 meter distance of the extinguisher access hole
to the engine compartment, within a 2 meter
distance to every appliance using a naked  ame
and, eventually, 1 extinguisher within 1 meter of
the steering wheel.
We advise a total capacity of at least 8A / 68B for
all the portable extinguishers, each of them with a
least a capacity of 5A / 34B. The CO2 extinguishers
have to be used for the kitchen or electrical  res.
The vessel is delivered with 1 CO2 extinguisher in
every engine compartment.
The location is de ned in the diagram below. This
location is the same for any of the 3 versions.
3. SAFETY
The main risks are related to the motorization
(§4.1), to the electrical system (§4.3) and to the
gas system (§4.4).
Please refer to the appropriate sections.
Fixed extinguisher system in the engine hold (access through the engine holds)
1 - Engine hold extinguisher release mechanism
2 - Tank power cut o
12
2 22
At the bottom of the
companionway to the
forward port cabin
At the bottom of the
companionway to the
starboard passageway
In the rear baseboard of the
bed in the aft starboard cabin
At the foot of the
companionway to the aft
port cabin
3