The main fault warning messages
are indicated on the display with the
appearance of an alarm window.
The type of fault identified is indicated
on the second line of the alarm window.
NON SERIOUS alarms are:
OVERTEMP. WASHING
Error during the wash phase.
It appears when the oven temperature
      

Switch off the oven and wait for it to
cool. If the problem persists call the
manufacturer technician or authorized
service agent.
NO H2O
This means there is no water: check
that the shutoff valve is open and that
there is water still coming from the
main. If there is no supply from the
main, inform the water company or
agency. If there is no problem with the
main, contact a manufacturer technician
or authorized service agent.
CORE PROBE
Core probe faulty. Should the
message appear, it is necessary to
check the connector is plugged into
the socket (10) properly. The oven can
continue to be used until the arrival of
a service technician, but without this
accessory.
CONDENS. PROBE. (if oven not
cooking or convection cooking).
Vapour condensation temperature
probe faulty. The condenser is
in operation continuously, but the
oven can still be used under close
observation in convection mode until
the arrival of a service technician.
OVEN BURNER BLOCKED
Blocked (may be caused by a
temporary failure in the gas supply or
problems with the gas line).
The blocked burners can be reset
manually.
If the problem persists, switch off
the oven immediately and call the
manufacturer technician or authorized
service agent.
PREALARM T. COMP.
An abnormally high temperature rise
has registered in the compartment
housing electrical components. The
oven can still be used under close
observation, until the arrival of a service
technician.
NO DRAIN
Indicates failure to drain water.
Drainage can be restored manually.
If the problem persists call the
manufacturer technician or authorized
service agent.
SERIAL FLASH
Indicates a faulty serial connection.
If the problem persists call the
manufacturer technician or authorized
service agent.
ATTENTION
Core temp. Probe
!!
24.2 - NON SERIOUS ALARM
24 SELF-DIAGNOSIS AND FAULT IDENTIFICATION
90027560rev00

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lainox COMPACT CEV Series and is the answer not in the manual?

Lainox COMPACT CEV Series Specifications

General IconGeneral
BrandLainox
ModelCOMPACT CEV Series
CategoryOven
LanguageEnglish

Related product manuals