Shutting Down And
Clean-up
STEP 1: Remove detergent suction
tube from container and insert into
one (1) gallon of fresh water. Flush
detergent lines with fresh water,
switch to the pump position and
continue to spray water allowing
burner to cool.
STEP 4: Squeeze trigger on spray
gun to relieve remaining pressure.
Move safety latch into its locked
position.
STEP 2: After water has cooled,
turn pump off. Turn main gas valve
off, then close the valve on the LP
tank. Secure the LP tank to the
machine when moving it.
STEP 3: Turn the water off. To
protect from freezing, pull the
trigger on spray gun to allow water
to drain from the system
Pump Switch
Maintenance