5: Commands and Levels
EDS1100/2100 Command Reference 127
enter
command mode in the CLI.
no command mode signon message
Clears the signon message displayed at boot time and when
entering
command mode.
Removes the gap timer, so forwarding depends on the line speed.
Removes the name of this line.
Uses a parity bit on the line for even parity.
Does not use a parity bit on the line.
Uses a parity bit on the line for odd parity.
Enters the serial line PPP level.
Applies Line Printer Daemon (LPD) protocol on the line.
Applies LPD or tunnel protocol on the line.
Applies Modbus ASCII protocol on the line.
Applies Modbus RTU protocol on the line.
Uses no protocol on the line.
Applies point-to-point protocol (PPP) on the line.
Applies tunnel protocol on the line.
Asserts line status with current configured values.
Displays the current status.
Shows the command mode settings for the current line.
Displays the last 20 commands entered during the current CLI
session.
Displays the current configuration.
Shows the line statistics.
Disables the line so data cannot be sent/received.
Enables the line so data can be sent/received.
Uses one stop bit after data on the line.
Uses two stop bits after data on the line.
Enters the configure-terminal level.
<line> = number of the terminal line (serial port) to be configured.
Enters the configure-terminal level for the network.
Refrains from terminating the line.
Enables 120 ohm line termination in RS485 half-duplex mode.
Sets the threshold in bytes. After this many bytes are received,
they are
forwarded without delay.
Enters the tunnel level.
<line> = number of the tunnel line (serial port) to be configured.
Stores the current configuration in permanent memory.
Sets the xoff character for use with software flow control on this
line.
The character may be input as text, control, decimal, or hex.
A control character has the form <control>C.
A decimal value character has the form \99.
A hex value character has the form 0xFF.