Operating Instructions – Mobility Wallbox Home / Home Pro 21
12 Technical data
Mobility Wallbox Home / Home Pro
Width x Height x Depth 351
x 486 x 126 mm
Weight
6.06 kg
Impact resistance rating of housing
IK08
Operating temperature
1)
-25 °C to +50 °C
Storage temperature
1)
-40 °C to +70 °C
Relative humidity during storage 5 % to 95 %
IP degree of protection
IP54
Pollution degree 3
Protection class I
Nominal voltage
220 ... 240 V / 380 ... 415 V
Nominal current 16 A
Nominal surge voltage
4 kV
Insulation voltage
500 V
Overvoltage category
III
Mains frequency 50 / 60
Hz
Circuit breaker 16 A, to be provided on the installation side
Fuse for the internal supply
8 A, slow-blow
Charging voltage
230 V / 400 V
Max. charging current
16 A
Max. charging power
11 kW
Residual current circuit breaker (RCD) optional: type A, with protective conductor monitoring
Short circuit fault current C16/C32 6 kA (Energy limiting class 3)
AC fault current
30 mA, to be provided on the installation side
DC residual fault current detection
6 mA, standard
Mains version
TN / TT / IT
Socket according to IEC 62196-1:2014
for charging cable Type 2
Charging mode
3
Supported charging conditions A, B, C, E, F
EMC classification Class B
Permissible installation area
freely accessible area
1) no direct sunlight