N PROBLEMS AND SOLUTIONS
Solution
Cause
Problem
Engine won't start
WARNING :
For further solutions to engine problems
please see the included "Lombardini"
instruction manual.
The equipment does not start
The equipment does not suck the
product
The equipment sucks but does not
reach the pressure desired
When pressing the trigger, the
pressure lowers considerably
The pressure is normal but the
product is not atomized
The atomization is imperfect
When releasing the trigger of the
gun, the equipment does not stop
(the motor runs slowly and the
piston rod keeps on going up and
down)
The petrol manifold is closed;
Engine is out of gas;
Cold engine;
Spark plug cable is disconnected or
damaged;
On/Off switch disconnected;
Breakdown of pressure transmitter;
Breakdown of motor electric control
box;
The line of material coming out of the
pump is already under pressure;
The product is solidified inside the
pump;
Suction filter clogged;
Suction ilter too fine;
The equipment sucks air;
Lack of product;
The equipment sucks air;
The drain valve is open;
The gaskets of the pumping group are
worn;
Suction or delivery valve dirty;
Nozzle too big or worn;
The product is too dense;
The filter of the gun-butt is too fine;
The nozzle is partially clogged;
The product is too dense;
The filter of the gun-butt is too fine;
The nozzle is worn;
The gaskets of the pumping group are
worn;
Suction or delivery valve dirty;
Drain valve defective;
Open the petrol manifold;
Refill gas tank;
Use choke;
Connect spark plug cable or replace
spark plug;
Ensure the On/Off switch is on the
“on” position and turn clockwise the
pressure control knob;
Verify and replace it, if necessary;
Verify and replace it, if necessary;
Open the drain valve to release
pressure in the circuit;
Open the drain valve to release
pressure in the circuit and stop the
machine. Disassemble the pumping
group and the pressure transmitter
and clean;
Clean or replace it;
Replace it with a larger-mesh filter
(with very dense products, remove
the filter);
Check the suction pipe;
Add the product;
Check the suction pipe;
Close the drain valve;
Replace the gaskets;
Disassemble the pumping group;
Replace it with a smaller one;
Dilute the product, if possible;
Replace it with a larger-mesh filter;
Clean or replace it;
Dilute the product, if possible;
Replace it with a larger-mesh filter;
Replace it;
Replace the gaskets;
Disassemble the pumping group and
clean;
Verify and replace it, if necessary;