LAUNCH KES-200 Cylinder Analysis
G-15
Fig.7-36
After sampling, KES-200 will display the tested
result in the bar graph mode as shown in
Fig.7-37.
Fig.7-37
Note:
The number below the bar graph is denotes
the cylinder number, while the value below
the cylinder number is the percent speed
drop of the relevant cylinder.
You can press [1] key to save the tested result.
Press [1] key, the screen will display as shown
in Fig.7-38.
Fig.7-38
z Press[[] [
] keys to select the waveform
name, and then press [ENTER] key to
save the tested result.
z Press [2] key, you may read the tested
result previously stored.
z Press [PRINT] to print the present tested
result.
z Press [ENTER] key to continue the test.
z Press [ESC] key to exit the test.
Note
The saved items will be marked with “*”.
At most 8 waveforms can be saved.
When all of the 8 items have been saved,
if you want to save a new waveform, the
new one will replace the old one.
When you select the item marked with
“*” to store a waveform, the new one
will replace the old one after pressing
[ENTER] key.
As the firing order of engines with 4 or
less than 4 cylinders is definite, so it is
not necessary to input firing order when
perform cylinder efficiency test for
these engines.
View Test Result
On the interface as shown in Fig.7-28, press [2]
key to select [2.VIEW], the screen will display
as shown in Fig.7-39.

Table of Contents