On the interface of “Bar graph/Peak wave”, user can
press [1] to view other saved waveform, or press
[ESC] to exit the waveform record.
Note:
♦ At most 8 waveforms can be saved.
♦ The saved address will be marked with “*”.
Analysis of Tested Waveform
The bar graph may indicate the test information in a
period of time:
z The difference between the maximum and
minimum values in the bar graph of relative
compression for cylinder should be less than
10%.
z The starting voltage and current should be in
accordance with the specifications of the
vehicle.
z Charging current should be in accordance with
the specifications of the alternator.