LAUNCH KES-200 PC Link
H-5
Note:
The saved address will be marked with “*”.
At most 8 waveforms can be saved. When
all of the 8 addresses have been saved, if
you want to save a new waveform, the new
one will replace the old one.
When you select the address marked with
“*” to store a waveform, the new one will
replace the old one after pressing [ENTER]
key.
The following operations can be done at present:
z Press [PRINT] key to print the waveform;
z Press [ESC] key to exit; or
z Press [ENTER] key to re-enter the relative
compression test data.
Note:
If the test cable is not connected properly, the
screen will be displayed as shown in Fig.7-53
after engine is started. It is necessary to press
[ESC] to exit the test, reconnect the test cable,
and perform the test again.
On the request to select the number of cylinders, as
shown in Fig.7-46, when select number “4” or “3”,
KES-200 will directly activate the relative compression
test after [ENTER] key is pressed. Engines with 4 or
less cylinders have the firing order fixed.
View the Tested Waveforms
On the second-level function menu, press [2] key to
select [2.View], the screen will display the interface as
shown in Fig.7-58.
Fig.7-58
Press [] or [] key to select a waveform record,
and then press [ENTER] key. The screen will display
the corresponding bar graph as shown in Fig.7-59.
Fig.7-59
Press [2] to select [2.Display], the screen will be
displayed as shown in Fig.7-60.
Fig.7-60
User can make choice between [1.Bar Graph] and
[2.Peak Waveform]. When pressing [] key to select
[2.Peak Waveform], the screen will display the peak
waveform corresponding to the bar graph, as shown
in Fig.7-61.