Page | 30 Proofer Operators Manual 1-2022 (English)
Copyright 2022 LBC Bakery Equipment Inc. Tulalip WA
Increase the value to increase the display and lower the
actual temperature.
Increase the value to increase the display and lower the
actual humidity.
Limit the range of temperature variance shown in degrees.
Limit the range of humidity variance shown in degrees.
Sets the range for PID control in degrees.
Sets the ratio of proportional off/on time to temperature
difference.
Sets the length of the PID cycle in seconds.
Sets the length of time in seconds for each humidity cycle.
Sets the "on" time in seconds for humidity in each cycle.
Sets how long the control will delay the turning on of the
cooling system in minutes.
Temperature difference between cooling off and cooling on.
Temperature difference between heating on and heating off.
How long the light will be on in seconds. "0.0" = light will be
on indefinitely.
Determines how long the alarm will sound before it turns off,
in seconds. "0.0" means the alarm will stay on indefinitely.
Length of the defrost time in minutes. "00" = no defrost.
Determines how long between starts of the defrost cycle in
hours. "00" = no defrost.
Determines what temperature ends the defrost cycle, when
a thermistor is imbedded in the evaporator.