Page | 31 Proofer Operators Manual 1-2022 (English)
Copyright 2022 LBC Bakery Equipment Inc. Tulalip WA
F19
Over temperature
alarm
Determines when the alarm will sound if the temperature
runs away.
140
32 - 200
F20
Maximum temp set
point
Determines how high the user can set the temperature.
105
32 - 140
F21
Minimum temp set
point
Determines how low the user can set the temperature.
34
0 - 32
F22
F/C
Determines the scale of the temperature display.
F
F - C
F23
Unattended
proofer delay
Determines how long the proofer can continue to humidify
without having the door opened in minutes.
45
0 - 99
F24
Open Door turn-off
delay
Determines how long the door can be left open in the
proofing mode before the unit turns off in minutes.
10
0 - 20
F25
Legacy option
"0" = for old retarders, "1" = for new retarders after the
addition of the door switch
0
0 - 1