15
time set to ≤23H, it means the load start timer or sensor
function. If the battery capacity is enough, the load will be
started at sunset. The load will work under timer setting
hours or stop working till sunrise.
When the load join into timer or sensor
mode, if the reset working time more than
actual night time, the load output will be
closed at sunrise, although the working time is not
reach to setting hours. For example, the local actual
night time is 10hours, user reset the working time at
night is 12hours, but 10hours later the output will be
closed automatically, the balance hours will be back to
zero. The load will be working with next sunset signal.
e) System Voltage Select
This parameter designed for
customers wide range voltage
requiring. The default display
“UT0”
system voltage 12/24v
auto.