BAODING LEAD FLUID TECHNOLOGY CO.,LTD.
Mail
leifu@leadfluid.net WEB
www.leadfluid.net
2
tubing length, import and export pressure using conditions change, please
consult our engineers.
If long time no use the peristaltic pump, please lift the briquetting of pump
head, release the tubing, to prevent the tube inner surface adhesion.
For extending the service life of the tubing, can move the tubing on a
regular basis, 200-300 - mm, will be alternating roller extrusion tubing
continue to use after partial replacement of the new location.
if the tubing burst in using, please timely clean up the spilled liquid, before
the use should check again whether the head roller pump running flexible,
if it is found that roller operation is not flexible, please relate our company.
If forced to use will fuel tubing wear and damage the pump head.
At the top knob of the pump head YT15, YT25, YZ35 t can adjust the
pressure, such as can't conveying liquid or the output pressure is not
enough, can be appropriately clockwise to normal output liquid.