16
MAINTENANCE
Perform the following maintenance once per year:
9 Check that Flow indicator lights up when water is flowing. A delay of a few
seconds is normal.
9 Test the magnetic valve regularly. Set the system in Away mode, open a faucet
and check that the system shuts the water supply off.
9 Clean the dirt filter. A blocked filter may cause problems in water supply or
water pressure. See installation manual.
If needed:
9 If the clock on the screen panel shows the wrong time after a blackout, change
the battery.
TECHNICAL DETAILS
LEAKOMATIC MI
Control unit
Power source 24VDC
Measures 126(W) x 74(H) x 30(D) mm
Wifi IEEE 802.11 b/g/n
Open/WEP/WPA/WPA2
DHCP
Valve unit
Screw thread ¾” - DN20
Pressure loss 0,30 bar
Max operation pressure 10 bar
Max flow 5,8 m3/h
Measures 90(W) x 225(H) x 125(D) mm
Operation temperature +0 .. +90 °C (frost-free)
Valve position during an
electrical blackout
NO – Normally Open