USER MANUAL

Control Unit Components

Describes the screen, indicators, buttons, and navigation elements of the control unit.

Valve Unit Overview

Provides dimensions and details for the valve unit.

Installation Requirements

Outlines conditions for flawless operation and warranty validity regarding installation.

How Leakomatic Works

Explains the function of the valve unit in protecting the piping system and monitoring water flow.

LEAKAGE TESTS

Pulse and Flow Indicators

Explains how Leakomatic differentiates water flow based on volume and time duration.

Flow Test Function

Details the Flow Test's purpose to prevent extended water flow beyond set limits.

Quick Test Operation

Describes the Quick Test's real-time reaction to sudden drip leaks and its index calculation.

Tightness Test Analysis

Explains the Tightness Test's long-term analysis for detecting hidden leaks over 24-hour periods.

LEAKOMATIC CLOUD

Wi-Fi Connection for Cloud

Details connecting the control unit to a local Wi-Fi network for cloud service access.

Wi-Fi Signal Strength Check

Emphasizes checking Wi-Fi signal strength for reliable cloud connectivity, not just signal bars.

Connecting to Wi-Fi Network

Step-by-step guide on selecting a network, entering the password, and establishing a Wi-Fi connection.

Activating Cloud Account

Instructions for creating and activating a Leakomatic Cloud account via the app or browser.

CONTROL UNIT OPERATION

Operating Modes Overview

Explains the three operational modes: Home, Away, and Pause, and how to switch between them.

Mode Indicator Functions

Details how the selected mode is indicated on the control unit's screen and indicator light.

ALARMS AND INDICATORS

Alarm Notifications

Explains how alarm lights and sounds are managed, including clearing alarms.

Alarm Types and Causes

Details specific alarms like Flow test, Tightness test, Quick test, and AUX inputs.

Flow Indicator Function

Describes the blue LED flow indicator's behavior during pulse and flow indications.

MENU NAVIGATION

Menu Navigation Controls

Explains how to use the arrow and button controls to navigate menus and change settings.

Menu Structure Overview

Visual representation of the system's menu hierarchy and available options.

SETTINGS MENU STRUCTURE

General Settings

Covers startup mode, sound alerts, language, time, and device restart options.

Flow Test Settings

Details alarm settings and time delays related to the Flow Test.

Quick Test Settings

Outlines alarm settings and index limits for the Quick Test.

Tightness Test Settings

Covers alarm settings, number of periods, duration, and delay for the Tightness Test.

Network Settings

Options for Wi-Fi configuration and cloud PIN management.

Valve Handling Settings

Configuration for conditioning and sensor diagnostics.

Input Handling Settings

Settings for AUX inputs, including water meter and sensor configurations.

Output Handling Settings

Configuration for AUX output activation and conditions.

MAIN MENU STATUS

Home Screen Status

Describes the information displayed on the main Home screen, including mode, time, and test status.

Tightness Test Status

Details the information shown on the Tightness Test status page.

Flow Test Status

Explains the data presented on the Flow Test status page.

Quick Test Status

Describes the Quick Test status page, including the index value and limit.

Activity Log

Explains the Activity Menu, which lists past events and alarms with date, time, and type.

Status Menu Inputs;Outputs

Details sensor data, AUX inputs, and valve status displayed in the Status Menu.

SETTINGS MENU

General Settings Configuration

Details settings for startup mode, noise, silence, pause time, language, time, timezone, restart, and factory reset.

TEST SETTINGS

Flow Test Parameters

Configuration options for Flow Test alarms and time delays.

Quick Test Parameters

Settings for Quick Test alarms, index limits, and alarm delays.

Tightness Test Parameters

Configuration for Tightness Test alarms, number of periods, duration, and delays.

INSTALLATION MENU

Network Configuration

Settings for Wi-Fi activation, network selection, and cloud PIN.

Valve Handling Configuration

Options for maintenance conditioning, time of day, and sensor diagnostics.

AUX1 Input Configuration

Settings for AUX1 input function, activation, and pulse unit/size for water meters.

ADVANCED INSTALLATION SETTINGS

AUX1 Calibration and AUX2 Configuration

Calibration for AUX1, and configuration for AUX2 input function and activation.

AUX2 Water Meter Settings

Settings for AUX2 pulse unit, size, and calibration for water meter configuration.

Analog Input Configuration

Settings for analog sensors, including min/max values, thresholds, and hysteresis.

Output Handling Configuration

Settings for AUX output activation and conditions for Home/Away modes or alarms.

SYSTEM MANAGEMENT

Restarting the Device

Instructions on how to restart the Leakomatic control unit via the menu or power cycle.

Restoring Factory Settings

Steps to reset the device to its original factory default configurations.

Battery Replacement

Guide on how to change the backup batteries for the screen clock.

MAINTENANCE AND TECHNICAL SPECIFICATIONS

Annual Maintenance Checks

Recommended yearly maintenance tasks for the Leakomatic system.

Technical Details Overview

Provides specifications for the control unit and valve unit, including dimensions and operating parameters.

DECLARATION OF CONFORMITY

Manufacturer Information

Identifies Leakomatic Ab as the manufacturer and provides contact details.

Product Identification

Lists the Leakomatic M4i product and its subparts.

Environment of Use

Specifies the intended environment of use for the product.

Compliance Standards

Lists the standards and specifications the product has been tested against.

INSTALLATION CERTIFICATE

Installation Details

Fields for recording installation date, address, serial number, installer, and customer information.

Installation Checks

Checklist for installer to confirm proper installation of components and tests.

Customer Training and Signatures

Section for confirming customer training and obtaining signatures from both installer and customer.

Leakomatic M4i Specifications