ALARMS
The alarm light flashes during the warning and stays on during the alarm.
Press the Clear button briefly to silence the warning and alarm sounds.
Keep the Clear button pressed to clear the alarm.
The system shuts off water only in case of an alarm. Silence the alarm by briefly
pressing the Clear button and find the cause of the alarm. The water will start to
flow again only after the alarm has been cleared.
The device warns before sounding an alarm if a delay has been set. The alarm must
be manually cleared whereas warnings can be automatically cleared through the
system after the cause of the alarm has passed.
You can set a time frame when the system stays silent to guarantee uninterrupted
sleep. Alternatively, you can permanently disable the alarm sound or only allow
sounds during a warning/alarm.
Alarm Warning
Description
Flow test Flow has continued longer than the set maximum time.
See further information in Flow test.
Tightness
test
The tightness test detects possible hidden leaks.
See further information in Tightness test.
Quick test The index limit of the Quick test has been surpassed.
See further information in Quick test.
AUX1 IN AUX1 input is activated.
AUX2 IN AUX2 input is activated.
Sensor There hasn’t been any pulse registered in the last seven days
FLOW INDICATOR
The blue LED light on the control unit is the flow indicator. It lights
up briefly during the pulse indication and stays lit up during flow
indication. The flow indicator has a 10 second delay during which
the device analyses and determines the flow type.