8.5.1.5 PrintGo-hold off distance
The setting provides a filtering of unrequested PrintGo-signals (e.g. PrintGo with
bounces or double releases). The value defines a length „x“ after the PrintGo-signal
in which every further signal will be ignored.
The input is carried out in the measurement which has been selected in the basic
settings.
The set value is shown on the accordant display field.
Figure 134
PrintGo-hold off distance
PrintGo with „chatters“:
Filtering active
PG Signal(s)
Double releases:
Text Text Text