Group 9 Disturbances/Trouble shooting Page 340
Release R2.0 LEIBINGER JET3
Overload of the charging
voltage amplifier.
Overload of charging voltate
amplifier.
Please check compressors
and all connections.
The compressor could not set
the compression within 120
sec.
Check pneum. connections
for leakages. Check com-
pressor and if necessary
exchange it.
Ink delivery is faulty.
Please check pump and
all connections.
Main pump could not place
the membrane to the central
position within 2,5 sec. dur-
ing the normal operation.
Air in the system.
Leakage.
Bleeding valve does not close
correctly.
Main pump is defect elec-
trically.
Main pump is defect mech-
anically.
Activate function perma-
nent bleeding for some
minutes.
Check for leakage
Check bleeding valve and if
necessary replace it.
Check main pump and if
necessary replace it.
Leakage in hydraulic has
been found. Please check
immediately.
Leakage sensor at the ca-
binet bottom reports liquid.
Check system for liquid and
repair.
Check leakage sensor for
dirt and if necessary clean
it.
During a stroke has been
generated, the next stroke
output has been already
initiated.
Increase font width.
Use other printing mode
(high speed mode).
Reduce height of total
printing image (Reduce
amount of dots).
The printing distance (PG-
distance) which is specified
in the job editor between two
prints is smaller than the
print.
Increase the PG-distance
value.
During a print the next
PrintGo-signal has been
already received.
Reduce font width.
Check signal encoder
(sensor).
Check signal encoder for
multi-identification during a
print.
Enlarge product distance.