Group 10 Equipping/Maintenance Page 345
Release R2.0 LEIBINGER JET3
10.2.1 Daily servicing work
The daily servicing work includes the checking of the print head and in particular of
the deflector unit, the charging electrode as well as of the guides for dirt. If necessary
the components must be cleaned as described in the chapter Cleaning.
10.2.2 Weekly servicing work
The weekly servicing work includes the checking of the spindles and of the guides
of the nozzle seal for dirt. If necessary the components must be cleaned as described
in the chapter Cleaning.
SERVICE WORK
This work must only be carried out by trained personnel or by Leibinger
service technicians!
10.2.3 Anual servicing work
The manufacturer recommends a regular servicing interval of 612 months.
SERVICE WORK
This work must only be carried out by trained personnel or by Leibinger
service technicians!