EasyManua.ls Logo

Leica TS03 - EDM Settings for Scale and PPM; EDM Settings - Projection Scale; EDM Settings - Individual PPM; EDM Settings - Signal Reflection

Leica TS03
202 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of fields
Field Option Description
Temp.Meas. Auto When a distance is measured using Meas
or
Dist, the temperature is read from the
instrument temperature sensor. The value is
displayed in the Temperature field. The
atmospheric ppm is recalculated and dis-
played in the Atmos PPM field. Measured
distances are corrected with the new atmos-
pheric ppm.
Single When pressing Temp, the temperature is
read from the instrument temperature sen-
sor. The value is displayed in the Tempera-
ture field. The atmospheric ppm is recalcula-
ted and displayed in the Atmos PPM field.
Manual The temperature value can be entered man-
ually.
This screen enables entry of the scale of projection. Coordinates are corrected
with the PPM parame
ter. Refer to "16.7 Scale Correction" for the application of
the values entered on this screen.
This screen enables the entry of individual scaling factors. Coordinates and dis-
tance me
asurements are corrected with the PPM parameter. Refer to "16.7
Scale Correction" for the application of the values entered on this screen.
This screen tests the EDM signal strength (reflection strength) in steps of 1%.
Enable
s o
ptimal aiming at distant, barely visible, targets. A percentage bar and
a beeping sound, indicate the reflection strength. The faster the beep the
stronger the reflection.
General handling
Handling of Geom.ppm Atmos. ppm Indiv. ppm
Slope distance Not applied Applied
Horizontal
distance
Not applied Applied Applied
Coordinates Applied Applied Applied
Exceptions
•
Set
out
Geometric reduction values are applied to calculate and display the hori-
zon
tal distance difference so that the position of points to be staked is
found correctly.
•
LandXML Data and HeXML
To import and use the measurements into Leica Infinity, the distances
rec
orded in LandXML differ from the distances on the instrument.
EDM Settings - Enter
Projec
tion Scale
EDM Settings - Enter
Individual PPM
ED
M Settings - EDM
Signal R
eflection
ppm handling
56 Settings
Not applied

Table of Contents