5.1004.8641.0 B
4-2 Operating Instructions
It is not advised to perform an M4USE Flush within an hour before a cluster cleaning, to
make sure the cleaning water has the optimal temperature during the cluster cleaning.
1. On the E-Link/ X-Link select:
1. Button
.
Figure 16. Empty buckets
Figure 17. Filled buckets
2. A pop up window will appear, presenting one of
the following situations:
1. All the M4USE buckets are empty (see figure
16 on page 4-2).
When the Flush starts, the Flush will rinse all
the buckets.
2. During the M4USE Flush, buckets filled with
milk will not be rinsed (see figure 17 on page
4-2).
If a full rinse is wanted, empty the filled
buckets first.
The M4USE Flush will take approximately 6 minutes to complete. The process will:
1. Start a cold water pre-rinse.
2. After the pre-rinse, a hot water cleaning with chemicals will rinse the lines and nozzle.
3. Finish with a cold water post-rinse.
The pre and post-rinse durations can be changed by the settings on the robot for the
local pre and local post-rinse duration. However, this also affects the local rinse hot water
and the USA local rinse.
in n o vato rs in agriculture