5.1004.8641.0 B
Maintenance 5-7
3. Select Tasks.
4. Select Feed portion.
5. At Entry gate button Open.
6. Go into the box through the entry gate.
7. Empty the feed bin.
8. Go out of the box through the entry gate.
Measure the feed Portion
The steps below must be done for all installed feeding valves.
1. In the field Select feed type select Edit and select the feed type.
2. Select Start dose.
3. Wait until the feed unit is finished.
4. Put a bucket on the scales.
5. Reset the scales to zero.
6. Remove the bucket.
7. Go into the box through the entry gate.
8. Put the feed from the feed bin into the bucket.
9. Go out of the box through the entry gate.
10. Put the bucket with the feed on the scales.
11. Calculate the weight of the feed and make a note of the weight.
12. Empty the bucket.
Adjust the Feed Portion
The steps below must be done for all installed feeding valves.
1. In the field Feed portion # and Calculated fill in the calculated weight.
2. Select Save portion sizes.