EasyManua.ls Logo

LELY E-LINK D 6060 - Beep; Worm Monitor (D 4060 Only)

LELY E-LINK D 6060
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SETUP menue
20 E-LINK D 6060 • D 4060
Beep
The beep indicates audibly that a key on the control box has
been pressed. The beep can be switched on or off and the
length of the beep can be varied (0..50 ms).
Worm monitor (D 4060 only)
When the control recognizes blocking of at least one of the two
worms (worms between rotor and compactor) the PU stop is
activated.
The PU stop will only be deactivated when the two worms
rotate again.
Worm monitoring becomes active only from a certain operating
speed: approx. 800 U/min.