Operation
134
9.4.2 Spraydos
The indicator lights of the segment switches and the master switch show the
spraying function.
In order for the operating terminal to automatically control the quantity applied per
hectare (l/ha) the following settings must be made:
Pulses/100 m
Pulses/l
Working width (m)
Segment distribution (m) and number of segments
Quantity to be applied (l/ha)
Valve type and control constant
A manual pressure setting is not possible in automatic mode.
If the spray pressure is to be adjusted manually,
Manual mode must be selected with the Manual/Automatic switch
and the spray pressure adjusted with the spray pressure switch.
There is no automatic control in Manual mode.
See also the Spraydos operating instructions.
9.4.3 Other operating terminals
See the separate operating instructions for the relevant operating terminals and
components.