14ACX - 1.5 to 5 Ton Air Conditioner / Page 106
AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS036-230A TXV 35,000 16.00 13.00 CX35-50/60C SL280UH110V60C 8259354
14ACXS036-230A TXV 35,000 16.00 13.00 CX35-50/60C SL280UH110XV60C 8259378
14ACXS036-230A TXV 34,800 16.00 13.00 CX35-50/60C SLP98UH090XV36C 8259357
14ACXS036-230A TXV 34,800 16.00 13.00 CX35-50/60C SLP98UH090XV48C 8259359
14ACXS036-230A TXV 35,200 16.00 13.00 CX35-50/60C SLP98UH110XV60C 8259366
14ACXS036-230A TXV 34,200 14.50 12.20 CX35-50/60C 8259350
14ACXS042-230A RFC 41,500 14.00 12.00 C33-49 7783121
14ACXS042-230A RFC 42,000 14.25 12.20 C33-62C 7782920
14ACXS042-230A RFC 41,500 14.00 12.20 C35-49C 8471048
14ACXS042-230A RFC 41,000 14.00 12.20 C35-60D 8471050
14ACXS042-230A RFC 41,500 14.00 12.20 CH33-43B 8452500
14ACXS042-230A RFC 41,500 14.00 12.20 CH33-43C 7628211
14ACXS042-230A RFC 42,000 14.00 12.20 CH33-49 7782981
14ACXS042-230A RFC 41,500 14.00 12.20 CH33-50/60C 7782992
14ACXS042-230A TXV 39,500 14.50 12.20 C33-36B EL180UH090E48B 7782859
14ACXS042-230A TXV 39,500 14.50 12.20 C33-36B EL180UH090XE48B 7627230
14ACXS042-230A TXV 39,000 14.00 11.50 C33-36B EL296UH045XV36B 7627224
14ACXS042-230A TXV 39,000 14.00 11.50 C33-36B EL296UH070XV36B 7627227
14ACXS042-230A TXV 39,500 14.50 12.20 C33-36B SL280UH090V36B 7782856
14ACXS042-230A TXV 39,500 14.50 12.20 C33-36B SL280UH090V48B 7627221
14ACXS042-230A TXV 39,500 14.50 12.20 C33-36B SL280UH090XV48B 7782857
14ACXS042-230A TXV 39,000 14.00 11.50 C33-36B SLP98UH070XV36B 7782858
14ACXS042-230A TXV 39,500 14.50 12.20 C33-36C EL180UH090E60C 7782867
14ACXS042-230A TXV 39,000 14.50 12.20 C33-36C EL180UH110E60C 7627260
14ACXS042-230A TXV 39,000 14.50 12.20 C33-36C EL180UH110XE60C 7782868
14ACXS042-230A TXV 39,000 14.50 12.20 C33-36C EL195UH090XE48C 7782865
14ACXS042-230A TXV 39,500 14.50 12.20 C33-36C EL195UH110XE60C 7782866
14ACXS042-230A TXV 39,000 14.50 12.20 C33-36C EL296UH090XE48C 7627254
14ACXS042-230A TXV 39,000 14.50 12.00 C33-36C EL296UH090XV36C 7627234
14ACXS042-230A TXV 39,000 14.50 12.20 C33-36C EL296UH090XV48C 7627237
14ACXS042-230A TXV 39,500 14.50 12.00 C33-36C EL296UH090XV60C 7627240
14ACXS042-230A TXV 39,500 14.50 12.20 C33-36C EL296UH110XE60C 7627257
14ACXS042-230A TXV 39,500 14.50 12.20 C33-36C EL296UH110XV60C 7627243
14ACXS042-230A TXV 39,500 14.50 12.20 C33-36C SL280UH090V60C 7627246
14ACXS042-230A TXV 39,500 14.50 12.20 C33-36C SL280UH090XV60C 7627248
14ACXS042-230A TXV 39,500 14.50 12.20 C33-36C SL280UH110V60C 7782864
14ACXS042-230A TXV 39,500 14.50 12.20 C33-36C SL280UH110XV60C 7627251
14ACXS042-230A TXV 39,000 14.50 12.00 C33-36C SLP98UH090XV36C 7782860
14ACXS042-230A TXV 39,000 14.50 12.20 C33-36C SLP98UH090XV48C 7782861
14ACXS042-230A TXV 39,500 14.50 12.00 C33-36C SLP98UH090XV60C 7782862
14ACXS042-230A TXV 39,500 14.50 12.20 C33-36C SLP98UH110XV60C 7782863
14ACXS042-230A TXV 41,000 15.10 12.50 C33-38B EL180UH090E48B 7627273
14ACXS042-230A TXV 41,000 15.10 12.50 C33-38B EL180UH090XE48B 7782872
14ACXS042-230A TXV 40,500 14.50 12.20 C33-38B EL296UH045XV36B 7627276
14ACXS042-230A TXV 40,500 14.50 12.20 C33-38B EL296UH070XV36B 7627267
14ACXS042-230A TXV 41,000 15.10 12.50 C33-38B SL280UH090V36B 7782870
14ACXS042-230A TXV 41,000 15.10 12.50 C33-38B SL280UH090V48B 7627270
14ACXS042-230A TXV 41,000 15.10 12.50 C33-38B SL280UH090XV48B 7782871
14ACXS042-230A TXV 40,500 14.50 12.20 C33-38B SLP98UH070XV36B 7782869
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

Related product manuals