14ACX - 1.5 to 5 Ton Air Conditioner / Page 107
AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS042-230A TXV 40,500 14.25 12.00 C33-38B 7627264
14ACXS042-230A TXV 39,500 14.50 12.20 C33-42 EL180UH090E48B 7782876
14ACXS042-230A TXV 39,500 14.50 12.20 C33-42 EL180UH090XE48B 7627288
14ACXS042-230A TXV 39,000 14.00 11.50 C33-42 EL296UH045XV36B 7782873
14ACXS042-230A TXV 39,000 14.00 11.50 C33-42 EL296UH070XV36B 7782874
14ACXS042-230A TXV 39,500 14.50 12.20 C33-42 SL280UH090V36B 7627282
14ACXS042-230A TXV 39,500 14.50 12.20 C33-42 SL280UH090V48B 7782875
14ACXS042-230A TXV 39,500 14.50 12.20 C33-42 SL280UH090XV48B 7627285
14ACXS042-230A TXV 39,000 14.00 11.50 C33-42 SLP98UH070XV36B 7627279
14ACXS042-230A TXV 41,500 15.50 12.50 C33-43B EL180UH090E48B 7627300
14ACXS042-230A TXV 41,500 15.50 12.50 C33-43B EL180UH090XE48B 7782881
14ACXS042-230A TXV 41,000 14.50 12.20 C33-43B EL296UH045XV36B 7627291
14ACXS042-230A TXV 41,000 14.50 12.20 C33-43B EL296UH070XV36B 7627294
14ACXS042-230A TXV 41,000 15.10 12.50 C33-43B SL280UH090V36B 7782879
14ACXS042-230A TXV 41,500 15.10 12.50 C33-43B SL280UH090V48B 7627297
14ACXS042-230A TXV 41,500 15.10 12.50 C33-43B SL280UH090XV48B 7782880
14ACXS042-230A TXV 41,000 14.50 12.20 C33-43B SLP98UH070XV36B 7782878
14ACXS042-230A TXV 41,000 14.25 12.00 C33-43B 7782877
14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C EL180UH090E60C 7627324
14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C EL180UH110E60C 7782889
14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C EL180UH110XE60C 7627327
14ACXS042-230A TXV 41,000 15.50 12.50 C33-43C EL195UH090XE48C 7782890
14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C EL195UH110XE60C 7782891
14ACXS042-230A TXV 41,000 15.50 12.50 C33-43C EL296UH090XE48C 7627330
14ACXS042-230A TXV 41,000 15.10 12.50 C33-43C EL296UH090XV36C 7627306
14ACXS042-230A TXV 41,000 15.10 12.50 C33-43C EL296UH090XV48C 7627309
14ACXS042-230A TXV 41,500 15.10 12.50 C33-43C EL296UH090XV60C 7782885
14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C EL296UH110XE60C 7627333
14ACXS042-230A TXV 41,500 15.10 12.50 C33-43C EL296UH110XV48C 7782884
14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C EL296UH110XV60C 7782886
14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C SL280UH090V60C 7627318
14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C SL280UH090XV60C 7782887
14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C SL280UH110V60C 7627321
14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C SL280UH110XV60C 7782888
14ACXS042-230A TXV 41,000 15.10 12.50 C33-43C SLP98UH090XV36C 7782882
14ACXS042-230A TXV 41,000 15.10 12.50 C33-43C SLP98UH090XV48C 7782883
14ACXS042-230A TXV 41,500 15.10 12.50 C33-43C SLP98UH090XV60C 7627312
14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C SLP98UH110XV60C 7627315
14ACXS042-230A TXV 41,000 14.25 12.00 C33-43C 7627303
14ACXS042-230A TXV 40,500 15.10 12.50 C33-48B EL180UH090E48B 7782894
14ACXS042-230A TXV 40,500 15.10 12.50 C33-48B EL180UH090XE48B 7627342
14ACXS042-230A TXV 40,500 14.50 12.20 C33-48B EL296UH045XV36B 7627336
14ACXS042-230A TXV 40,000 14.50 12.00 C33-48B EL296UH070XV36B 7627339
14ACXS042-230A TXV 40,500 15.00 12.50 C33-48B SL280UH090V36B 7782895
14ACXS042-230A TXV 40,500 15.00 12.50 C33-48B SL280UH090V48B 7627345
14ACXS042-230A TXV 40,500 15.00 12.50 C33-48B SL280UH090XV48B 7782896
14ACXS042-230A TXV 40,000 14.50 12.00 C33-48B SLP98UH070XV36B 7782893
14ACXS042-230A TXV 40,000 14.00 11.50 C33-48B 7782892
14ACXS042-230A TXV 41,000 15.10 12.50 C33-48C EL180UH090E60C 7782897
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.