14ACX - 1.5 to 5 Ton Air Conditioner / Page 111
AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS042-230A TXV 41,500 15.50 12.50 C35-48C EL296UH110XE60C 8258333
14ACXS042-230A TXV 41,500 15.10 12.50 C35-48C EL296UH110XV48C 8258318
14ACXS042-230A TXV 41,500 15.50 12.50 C35-48C EL296UH110XV60C 8258321
14ACXS042-230A TXV 41,500 15.50 12.50 C35-48C SL280UH090V60C 8258325
14ACXS042-230A TXV 41,500 15.50 12.50 C35-48C SL280UH090XV60C 8258323
14ACXS042-230A TXV 41,500 15.50 12.50 C35-48C SL280UH110V60C 8258326
14ACXS042-230A TXV 41,500 15.50 12.50 C35-48C SL280UH110XV60C 8258308
14ACXS042-230A TXV 41,000 15.10 12.50 C35-48C SLP98UH090XV36C 8258315
14ACXS042-230A TXV 41,000 15.10 12.50 C35-48C SLP98UH090XV48C 8258317
14ACXS042-230A TXV 41,500 15.10 12.50 C35-48C SLP98UH090XV60C 8258338
14ACXS042-230A TXV 41,500 15.50 12.50 C35-48C SLP98UH110XV60C 8258340
14ACXS042-230A TXV 41,000 14.25 12.00 C35-48C 8258307
14ACXS042-230A TXV 42,000 16.00 13.00 C35-49C EL180UH090E60C 8258355
14ACXS042-230A TXV 42,000 16.00 13.00 C35-49C EL180UH110E60C 8258367
14ACXS042-230A TXV 42,000 16.00 13.00 C35-49C EL180UH110XE60C 8258356
14ACXS042-230A TXV 41,500 15.50 12.50 C35-49C EL195UH090XE48C 8258368
14ACXS042-230A TXV 42,000 15.50 12.50 C35-49C EL195UH110XE60C 8258345
14ACXS042-230A TXV 41,500 15.50 12.50 C35-49C EL296UH090XE48C 8258370
14ACXS042-230A TXV 41,500 15.50 12.50 C35-49C EL296UH090XV36C 8258372
14ACXS042-230A TXV 41,500 15.50 12.50 C35-49C EL296UH090XV48C 8258373
14ACXS042-230A TXV 42,000 15.50 12.50 C35-49C EL296UH090XV60C 8258375
14ACXS042-230A TXV 42,000 15.50 12.50 C35-49C EL296UH110XE60C 8258358
14ACXS042-230A TXV 42,000 15.50 12.50 C35-49C EL296UH110XV48C 8258346
14ACXS042-230A TXV 42,000 15.50 12.50 C35-49C EL296UH110XV60C 8258360
14ACXS042-230A TXV 42,000 16.00 13.00 C35-49C SL280UH090V60C 8258348
14ACXS042-230A TXV 42,000 16.00 13.00 C35-49C SL280UH090XV60C 8258362
14ACXS042-230A TXV 42,000 15.50 12.50 C35-49C SL280UH110V60C 8258350
14ACXS042-230A TXV 42,000 15.50 12.50 C35-49C SL280UH110XV60C 8258363
14ACXS042-230A TXV 41,500 15.50 12.50 C35-49C SLP98UH090XV36C 8258351
14ACXS042-230A TXV 41,500 15.50 12.50 C35-49C SLP98UH090XV48C 8258353
14ACXS042-230A TXV 42,000 15.50 12.50 C35-49C SLP98UH090XV60C 8258365
14ACXS042-230A TXV 42,000 15.50 12.50 C35-49C SLP98UH110XV60C 8258343
14ACXS042-230A TXV 41,500 14.25 12.20 C35-49C 8258341
14ACXS042-230A TXV 41,000 15.50 12.50 C35-50/60C EL180UH090E60C 8258404
14ACXS042-230A TXV 41,000 15.50 12.50 C35-50/60C EL180UH110E60C 8258385
14ACXS042-230A TXV 41,000 15.50 12.50 C35-50/60C EL180UH110XE60C 8258406
14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C EL195UH090XE48C 8258387
14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C EL195UH110XE60C 8258408
14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH090XE48C 8258388
14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH090XV36C 8258409
14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH090XV48C 8258390
14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH090XV60C 8258394
14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH110XE60C 8258391
14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH110XV48C 8258396
14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH110XV60C 8258393
14ACXS042-230A TXV 41,500 15.10 12.50 C35-50/60C SL280UH090V60C 8258397
14ACXS042-230A TXV 41,500 15.10 12.50 C35-50/60C SL280UH090XV60C 8258378
14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C SL280UH110V60C 8258399
14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C SL280UH110XV60C 8258380
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.