EasyManua.ls Logo

Lennox 14ACx–024-230A02 - Page 112

Lennox 14ACx–024-230A02
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14ACX - 1.5 to 5 Ton Air Conditioner / Page 112
AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C SLP98UH090XV36C 8258401
14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C SLP98UH090XV48C 8258382
14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C SLP98UH090XV60C 8258403
14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C SLP98UH110XV60C 8258383
14ACXS042-230A TXV 40,500 14.25 12.00 C35-50/60C 8258377
14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL180UH090E60C 8258419
14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL180UH110E60C 8258439
14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL180UH110XE60C 8258421
14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL195UH090XE48C 8258441
14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL195UH110XE60C 8258423
14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL296UH090XE48C 8258443
14ACXS042-230A TXV 42,000 15.50 12.50 C35-60C EL296UH090XV36C 8258424
14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL296UH090XV48C 8258444
14ACXS042-230A TXV 42,000 15.50 12.50 C35-60C EL296UH090XV60C 8258426
14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL296UH110XE60C 8258429
14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL296UH110XV48C 8258428
14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL296UH110XV60C 8258431
14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C SL280UH090V60C 8258413
14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C SL280UH090XV60C 8258432
14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C SL280UH110V60C 8258414
14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C SL280UH110XV60C 8258434
14ACXS042-230A TXV 42,000 15.50 12.50 C35-60C SLP98UH090XV36C 8258416
14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C SLP98UH090XV48C 8258436
14ACXS042-230A TXV 42,000 15.50 12.50 C35-60C SLP98UH090XV60C 8258418
14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C SLP98UH110XV60C 8258438
14ACXS042-230A TXV 42,000 14.25 12.20 C35-60C 8258411
14ACXS042-230A TXV 42,000 16.00 13.00 C35-60D EL180UH135E60D 8258451
14ACXS042-230A TXV 42,000 15.50 12.50 C35-60D EL195UH135XE60D 8258448
14ACXS042-230A TXV 42,000 15.50 12.50 C35-60D EL296UH135XE60D 8258452
14ACXS042-230A TXV 42,000 16.00 13.00 C35-60D SL280UH135V60D 8258449
14ACXS042-230A TXV 41,500 14.25 12.20 C35-60D 8258446
14ACXS042-230A TXV 41,500 14.00 12.20 CBX25UH-042 7627464
14ACXS042-230A TXV 42,000 14.50 12.50 CBX25UH-048 7782935
14ACXS042-230A TXV 42,000 15.10 12.50 CBX25UHV-042 7627467
14ACXS042-230A TXV 42,000 15.50 12.50 CBX25UHV-048 7782936
14ACXS042-230A TXV 41,500 15.50 12.50 CBX27UH-042 7627461
14ACXS042-230A TXV 42,000 15.10 12.50 CBX27UH-048 7782934
14ACXS042-230A TXV 40,500 14.00 12.20 CBX32M-042 7627470
14ACXS042-230A TXV 41,500 14.25 12.20 CBX32M-048 7627472
14ACXS042-230A TXV 42,000 15.10 12.50 CBX32MV-048 7627475
14ACXS042-230A TXV 42,000 15.00 12.50 CBX40UHV-042 7627477
14ACXS042-230A TXV 42,000 15.00 12.50 CBX40UHV-048 7782937
14ACXS042-230A TXV 40,500 15.10 12.50 CH23-51 EL180UH090E60C 7627480
14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 EL180UH110E60C 7782938
14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 EL180UH110XE60C 7627483
14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 EL296UH090XV48C 7782939
14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 EL296UH090XV60C 7627487
14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 EL296UH110XV48C 7627489
14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 EL296UH110XV60C 7627492
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

Related product manuals