14ACX - 1.5 to 5 Ton Air Conditioner / Page 113
AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS042-230A TXV 40,500 15.10 12.50 CH23-51 SL280UH090V60C 7627494
14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 SL280UH110V60C 7782940
14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 SL280UH110XV60C 7782941
14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 SLP98UH090XV48C 7627498
14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 SLP98UH090XV60C 7782942
14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 SLP98UH110XV60C 7627501
14ACXS042-230A TXV 40,500 15.50 12.50 CH23-65 EL180UH090E60C 7782943
14ACXS042-230A TXV 40,500 15.50 12.50 CH23-65 EL180UH110E60C 7627504
14ACXS042-230A TXV 40,500 15.50 12.50 CH23-65 EL180UH110XE60C 7782944
14ACXS042-230A TXV 40,500 15.10 12.50 CH23-65 EL296UH090XV48C 7782945
14ACXS042-230A TXV 40,500 15.10 12.50 CH23-65 EL296UH090XV60C 7627509
14ACXS042-230A TXV 40,500 15.10 12.50 CH23-65 EL296UH110XV48C 7782946
14ACXS042-230A TXV 40,500 15.10 12.50 CH23-65 EL296UH110XV60C 7627512
14ACXS042-230A TXV 41,000 15.50 12.50 CH23-65 SL280UH090V60C 7782947
14ACXS042-230A TXV 40,500 15.50 12.50 CH23-65 SL280UH110V60C 7627515
14ACXS042-230A TXV 40,500 15.50 12.50 CH23-65 SL280UH110XV60C 7782948
14ACXS042-230A TXV 40,500 15.10 12.50 CH23-65 SLP98UH090XV48C 7627518
14ACXS042-230A TXV 40,500 15.10 12.50 CH23-65 SLP98UH090XV60C 7782949
14ACXS042-230A TXV 40,500 15.10 12.50 CH23-65 SLP98UH110XV60C 7627521
14ACXS042-230A TXV 40,500 15.10 12.50 CH33-42B EL180UH090E48B 7782950
14ACXS042-230A TXV 40,500 15.10 12.50 CH33-42B EL180UH090XE48B 7627524
14ACXS042-230A TXV 40,000 14.50 12.00 CH33-42B EL296UH070XV36B 7782951
14ACXS042-230A TXV 40,500 15.00 12.50 CH33-42B SL280UH090V36B 7627527
14ACXS042-230A TXV 40,500 15.00 12.50 CH33-42B SL280UH090V48B 7782952
14ACXS042-230A TXV 40,500 15.00 12.50 CH33-42B SL280UH090XV48B 7627530
14ACXS042-230A TXV 40,000 14.50 12.00 CH33-42B SLP98UH070XV36B 7782953
14ACXS042-230A TXV 42,000 15.50 12.50 CH33-43B EL180UH090E48B 8565949
14ACXS042-230A TXV 42,000 15.50 12.50 CH33-43B EL180UH090XE48B 8565950
14ACXS042-230A TXV 41,500 15.00 12.50 CH33-43B EL296UH045XV36B 7627533
14ACXS042-230A TXV 41,500 15.00 12.50 CH33-43B EL296UH070XV36B 7627536
14ACXS042-230A TXV 42,000 15.50 12.50 CH33-43B SL280UH090V36B 7782955
14ACXS042-230A TXV 42,000 15.50 12.50 CH33-43B SL280UH090V48B 7627539
14ACXS042-230A TXV 42,000 15.50 12.50 CH33-43B SL280UH090XV48B 7782956
14ACXS042-230A TXV 41,500 15.00 12.50 CH33-43B SLP98UH070XV36B 7782954
14ACXS042-230A TXV 41,000 14.50 12.20 CH33-43B SLP98UH090XV36B 7627542
14ACXS042-230A TXV 41,500 14.00 12.20 CH33-43B 8452497
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL180UH090E60C 7627545
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL180UH110E60C 7782958
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL180UH110XE60C 7627548
14ACXS042-230A TXV 41,000 15.50 12.50 CH33-43C EL195UH090XE48C 7782959
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL195UH110XE60C 7627551
14ACXS042-230A TXV 41,000 15.50 12.50 CH33-43C EL296UH090XE48C 7782960
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH090XV36C 7627554
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH090XV48C 7782961
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH090XV60C 7627557
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH110XE60C 7782962
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH110XV48C 7627560
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH110XV60C 7782963
14ACXS042-230A TXV 42,000 16.00 13.00 CH33-43C SL280UH090V60C 7627563
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.