14ACX - 1.5 to 5 Ton Air Conditioner / Page 114
AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS042-230A TXV 42,000 16.00 13.00 CH33-43C SL280UH090XV60C 7782964
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C SL280UH110V60C 7627566
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C SL280UH110XV60C 7782965
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C SLP98UH090XV36C 7627569
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C SLP98UH090XV48C 7782966
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C SLP98UH090XV60C 7627572
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C SLP98UH110XV60C 7782967
14ACXS042-230A TXV 41,500 14.00 12.20 CH33-43C 7782957
14ACXS042-230A TXV 41,000 15.10 12.50 CH33-44/48B EL180UH090E48B 7627575
14ACXS042-230A TXV 41,000 15.10 12.50 CH33-44/48B EL180UH090XE48B 7782968
14ACXS042-230A TXV 40,500 14.50 12.20 CH33-44/48B EL296UH070XV36B 7627578
14ACXS042-230A TXV 41,000 15.10 12.50 CH33-44/48B SL280UH090V36B 7782969
14ACXS042-230A TXV 41,000 15.10 12.50 CH33-44/48B SL280UH090V48B 7627581
14ACXS042-230A TXV 41,000 15.10 12.50 CH33-44/48B SL280UH090XV48B 7782970
14ACXS042-230A TXV 40,500 14.50 12.20 CH33-44/48B SLP98UH070XV36C 7627584
14ACXS042-230A TXV 41,000 15.00 12.50 CH33-48 EL180UH090E48B 8552650
14ACXS042-230A TXV 41,000 15.50 12.50 CH33-48C EL180UH090E60C 7782971
14ACXS042-230A TXV 41,000 15.50 12.50 CH33-48C EL180UH110E60C 7627587
14ACXS042-230A TXV 41,000 15.50 12.50 CH33-48C EL180UH110XE60C 7782972
14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C EL195UH090XE48C 7627590
14ACXS042-230A TXV 41,500 15.10 12.50 CH33-48C EL195UH110XE60C 7782973
14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH090XE48C 7627593
14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH090XV36C 7782974
14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH090XV48C 7627596
14ACXS042-230A TXV 41,500 15.10 12.50 CH33-48C EL296UH090XV60C 7782975
14ACXS042-230A TXV 41,500 15.10 12.50 CH33-48C EL296UH110XE60C 7627599
14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH110XV48C 7782976
14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH110XV60C 7627602
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-48C SL280UH090V60C 7782977
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-48C SL280UH090XV60C 7627605
14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C SL280UH110V60C 7782978
14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C SL280UH110XV60C 7627608
14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C SLP98UH090XV36C 7782979
14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C SLP98UH090XV48C 7627611
14ACXS042-230A TXV 41,500 15.10 12.50 CH33-48C SLP98UH090XV60C 7782980
14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C SLP98UH110XV60C 7627615
14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 EL180UH090E60C 7782982
14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 EL180UH110E60C 7627621
14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 EL180UH110XE60C 7782983
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-49 EL195UH090XE48C 7627624
14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 EL195UH110XE60C 7782984
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-49 EL296UH090XE48C 7627628
14ACXS042-230A TXV 41,500 15.50 12.50 CH33-49 EL296UH090XV36C 7782985
14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH090XV48C 7627631
14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH090XV60C 7782986
14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH110XE60C 7627634
14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH110XV48C 7782987
14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH110XV60C 7627637
14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 SL280UH090V60C 7782988
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.