EasyManua.ls Logo

Lennox 14ACx–024-230A02 - Page 31

Lennox 14ACx–024-230A02
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14ACX - 1.5 to 5 Ton Air Conditioner / Page 31
AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-048-230 TXV 48,000 14.25 12.00 C35-48C SLP98UH110XV60C 8267524
14ACX-048-230 TXV 48,000 15.00 12.50 C35-49C EL180UH090E60C 8267549
14ACX-048-230 TXV 48,000 14.00 12.00 C35-49C EL180UH110E60C 8267550
14ACX-048-230 TXV 48,000 14.00 12.00 C35-49C EL180UH110XE60C 8267551
14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C EL195UH090XE48C 8267560
14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C EL195UH110XE60C 8267555
14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C EL296UH090XE48C 8267554
14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C EL296UH090XV48C 8267557
14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C EL296UH090XV60C 8267558
14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C EL296UH110XE60C 8267556
14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C EL296UH110XV48C 8267559
14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C EL296UH110XV60C 8267548
14ACX-048-230 TXV 48,000 15.00 12.50 C35-49C SL280UH090V60C 8267552
14ACX-048-230 TXV 48,000 15.00 12.50 C35-49C SL280UH090XV60C 8267553
14ACX-048-230 TXV 48,000 15.00 12.50 C35-49C SL280UH110V60C 8267543
14ACX-048-230 TXV 48,000 15.00 12.50 C35-49C SL280UH110XV60C 8267544
14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C SLP98UH090XV48C 8267545
14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C SLP98UH090XV60C 8267546
14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C SLP98UH110XV60C 8267547
14ACX-048-230 TXV 48,000 14.00 11.70 C35-49C 8267542
14ACX-048-230 TXV 47,500 14.50 12.00 C35-50/60C EL180UH090E60C 8267567
14ACX-048-230 TXV 48,000 14.00 11.70 C35-50/60C EL180UH110E60C 8267568
14ACX-048-230 TXV 48,000 14.00 11.70 C35-50/60C EL180UH110XE60C 8267569
14ACX-048-230 TXV 47,500 14.25 12.00 C35-50/60C EL195UH090XE48C 8267578
14ACX-048-230 TXV 47,500 14.25 12.00 C35-50/60C EL195UH110XE60C 8267573
14ACX-048-230 TXV 47,500 14.25 12.00 C35-50/60C EL296UH090XE48C 8267572
14ACX-048-230 TXV 47,500 14.00 11.70 C35-50/60C EL296UH090XV48C 8267575
14ACX-048-230 TXV 47,500 14.00 11.70 C35-50/60C EL296UH090XV60C 8267576
14ACX-048-230 TXV 47,500 14.25 12.00 C35-50/60C EL296UH110XE60C 8267574
14ACX-048-230 TXV 47,500 14.25 11.70 C35-50/60C EL296UH110XV48C 8267577
14ACX-048-230 TXV 47,500 14.00 11.70 C35-50/60C EL296UH110XV60C 8267566
14ACX-048-230 TXV 47,500 14.25 12.00 C35-50/60C SL280UH090V60C 8267570
14ACX-048-230 TXV 47,500 14.25 12.00 C35-50/60C SL280UH090XV60C 8267571
14ACX-048-230 TXV 47,500 14.25 12.00 C35-50/60C SL280UH110V60C 8267561
14ACX-048-230 TXV 47,500 14.25 12.00 C35-50/60C SL280UH110XV60C 8267562
14ACX-048-230 TXV 47,500 14.00 11.70 C35-50/60C SLP98UH090XV48C 8267563
14ACX-048-230 TXV 47,500 14.00 11.70 C35-50/60C SLP98UH090XV60C 8267564
14ACX-048-230 TXV 47,500 14.00 11.70 C35-50/60C SLP98UH110XV60C 8267565
14ACX-048-230 TXV 48,000 15.10 12.50 C35-60C EL180UH090E60C 8267586
14ACX-048-230 TXV 48,000 15.00 12.50 C35-60C EL180UH110E60C 8267587
14ACX-048-230 TXV 48,000 15.00 12.50 C35-60C EL180UH110XE60C 8267588
14ACX-048-230 TXV 48,000 14.50 12.50 C35-60C EL195UH090XE48C 8267597
14ACX-048-230 TXV 48,000 15.00 12.50 C35-60C EL195UH110XE60C 8267592
14ACX-048-230 TXV 48,000 14.50 12.50 C35-60C EL296UH090XE48C 8267591
14ACX-048-230 TXV 48,000 14.50 12.00 C35-60C EL296UH090XV48C 8267594
14ACX-048-230 TXV 48,000 14.50 12.00 C35-60C EL296UH090XV60C 8267595
14ACX-048-230 TXV 48,000 15.00 12.50 C35-60C EL296UH110XE60C 8267593
14ACX-048-230 TXV 48,000 15.00 12.50 C35-60C EL296UH110XV48C 8267596
14ACX-048-230 TXV 48,000 14.50 12.50 C35-60C EL296UH110XV60C 8267585
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.