EasyManua.ls Logo

Lennox 14ACx–024-230A02 - Page 32

Lennox 14ACx–024-230A02
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14ACX - 1.5 to 5 Ton Air Conditioner / Page 32
AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-048-230 TXV 48,000 15.10 12.50 C35-60C SL280UH090V60C 8267589
14ACX-048-230 TXV 48,000 15.10 12.50 C35-60C SL280UH090XV60C 8267590
14ACX-048-230 TXV 48,000 15.00 12.50 C35-60C SL280UH110V60C 8267580
14ACX-048-230 TXV 48,000 15.00 12.50 C35-60C SL280UH110XV60C 8267581
14ACX-048-230 TXV 48,000 14.50 12.00 C35-60C SLP98UH090XV48C 8267582
14ACX-048-230 TXV 48,000 14.50 12.00 C35-60C SLP98UH090XV60C 8267583
14ACX-048-230 TXV 48,000 14.50 12.50 C35-60C SLP98UH110XV60C 8267584
14ACX-048-230 TXV 48,000 14.00 11.70 C35-60C 8267579
14ACX-048-230 TXV 48,000 15.00 12.50 C35-60D EL180UH135E60D 8267601
14ACX-048-230 TXV 48,000 14.25 12.00 C35-60D EL195UH135XE60D 8267604
14ACX-048-230 TXV 48,000 14.25 12.00 C35-60D EL296UH135XE60D 8267599
14ACX-048-230 TXV 48,000 14.50 12.00 C35-60D EL296UH135XV60D 8267600
14ACX-048-230 TXV 48,000 15.00 12.50 C35-60D SL280UH135V60D 8267602
14ACX-048-230 TXV 48,000 14.50 12.00 C35-60D SLP98UH135XV60D 8267603
14ACX-048-230 TXV 48,000 14.00 11.70 C35-60D 8267598
14ACX-048-230 TXV 48,000 14.50 12.00 CBX25UH-048 7486446
14ACX-048-230 TXV 48,000 14.50 12.50 CBX25UHV-048 7486447
14ACX-048-230 TXV 48,000 14.50 12.00 CBX27UH-048 7486448
14ACX-048-230 TXV 48,000 15.00 12.50 CBX27UH-060 7486449
14ACX-048-230 TXV 48,000 14.25 12.00 CBX32M-048 7486450
14ACX-048-230 TXV 48,000 14.25 12.00 CBX32M-060 7486451
14ACX-048-230 TXV 48,000 14.25 12.00 CBX32MV-048 7486452
14ACX-048-230 TXV 48,000 14.50 12.00 CBX32MV-060 7486453
14ACX-048-230 TXV 47,500 14.50 12.00 CBX40UHV-048 7486454
14ACX-048-230 TXV 48,000 14.50 12.00 CBX40UHV-060 7486455
14ACX-048-230 TXV 46,000 14.00 11.70 CH23-51 EL180UH090E48B 7486456
14ACX-048-230 TXV 45,500 14.00 11.70 CH23-51 EL180UH110E60C 7486457
14ACX-048-230 TXV 45,500 14.00 11.70 CH23-51 EL180UH110XE60C 7486458
14ACX-048-230 TXV 47,000 14.25 11.70 CH23-65 EL180UH090E48B 7486459
14ACX-048-230 TXV 47,000 14.50 12.00 CH23-65 EL180UH090E60C 7486461
14ACX-048-230 TXV 47,000 14.25 11.70 CH23-65 EL180UH090XE48B 7486460
14ACX-048-230 TXV 46,500 14.50 12.00 CH23-65 EL180UH110E60C 7486462
14ACX-048-230 TXV 46,500 14.50 12.00 CH23-65 EL180UH110XE60C 7486463
14ACX-048-230 TXV 48,000 15.00 12.50 CH23-68 EL180UH135E60D 7486467
14ACX-048-230 TXV 48,000 14.50 12.00 CH23-68 EL195UH135XE60D 7486465
14ACX-048-230 TXV 48,000 14.50 12.00 CH23-68 EL296UH135XE60D 7486466
14ACX-048-230 TXV 48,000 14.00 11.70 CH23-68 7486464
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-43B EL180UH090E48B 7486468
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-43B EL180UH090XE48B 7486469
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-43C EL180UH090E60C 7486478
14ACX-048-230 TXV 48,000 14.25 12.00 CH33-43C EL180UH110E60C 7486479
14ACX-048-230 TXV 48,000 14.25 12.00 CH33-43C EL180UH110XE60C 7486480
14ACX-048-230 TXV 47,500 14.25 12.00 CH33-43C EL195UH090XE48C 7486470
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-43C EL195UH110XE60C 7486472
14ACX-048-230 TXV 47,500 14.25 12.00 CH33-43C EL296UH090XE48C 7486471
14ACX-048-230 TXV 48,000 14.25 12.00 CH33-43C EL296UH090XV48C 7486474
14ACX-048-230 TXV 48,000 14.25 11.70 CH33-43C EL296UH090XV60C 7486475
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-43C EL296UH110XE60C 7486473
14ACX-048-230 TXV 48,000 14.25 12.00 CH33-43C EL296UH110XV48C 7486476
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

Related product manuals