14HPX
Service Literature
Revised April, 2017
INSTALLATION AND SERVICE
PROCEDURE
LOUVERED
NON-LOUVERED
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause personal injury, loss of life, or
damage to property.
Installation and service must be performed by a licensed
professional installer (or equivalent) or a service agency.
IMPORTANT
This unit must be matched with an indoor coil as
specified in Lennox Product Specification bulletin. Coils
previously charged with HCFC-22 must be flushed.
WARNING
Electric Shock Hazard. Can cause injury or
death. Unit must be grounded in
accordance with national and local codes.
Line voltage is present at all components
when unit is not in operation on units with
single‐pole contactors. Disconnect all
remote electric power supplies before
opening access panel. Unit may have
multiple power supplies.
TABLE OF CONTENTS
Model Number Identification 2......................
Typical Serial Number Identification 2..............
Specifications 2.................................
Electrical Data 4................................
Unit Dimensions 7.................................
Typical Unit Parts Arrangement 8...................
General Information 9.............................
Operating Gauge Set and Service Valves 9...........
Unit Placement 12.................................
Removing and Installing Louvers 13.................
New or Replacement Line Set 15....................
Brazing Connections 17...........................
Flushing Line Set and Indoor Coil 20................
Installing Indoor Metering Device 21................
Leak Test Line Set and Indoor Coil 22...............
Evacuating Line Set and Indoor Coil 23.............
Electrical Connections 24..........................
System Operation (14HPX-XXX-230-01 through -016)26
Defrost System (14HPX-XXX-230-01 through -016) 26.
System Operation (14HPX-XXX-230-017) 31.........
Defrost System (14HPX-XXX-230-017) 31............
Maintenance 32...................................
Start-Up and Performance Checklist 35..............
Sequence of Operations 36.........................
Servicing Unit Void of Charge 40....................
Start-Up 40.......................................
System Refrigerant 40.............................
The Merit
®
14HPX model is designed for use with
HFC-410A refrigerant only. This unit must be installed with
an approved indoor air handler or coil. See the Lennox
14HPX Product Specification bulletin (EHB) for approved
indoor component matchups.
This outdoor unit is designed for use in systems that use the
following refrigerant metering device:
Check thermal expansion valve (CTXV)
IMPORTANT
The Clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs, HCFCs and HFCs) as of July 1, 1992.
Approved methods of recovery, recycling or reclaiming
must be followed. Fines and/or incarceration may be
levied for noncompliance.
Question and Answer IconNeed help?

Do you have a question about the Lennox 14HPX-036-230-17 and is the answer not in the manual?

Lennox 14HPX-036-230-17 Specifications

General IconGeneral
BrandLennox
Model14HPX-036-230-17
CategoryHeat Pump
LanguageEnglish

Summary

Product Identification and Specifications

Model Number Identification

Interpreting the unit's model number for specific configurations.

Unit Specifications

Technical data including sound rating, refrigerant charge, and fan specs.

Electrical Data

Electrical requirements, voltage, ampacity, and protection ratings.

Installation Procedures

Unit Dimensions and Parts

Physical dimensions, parts arrangement, and unit placement guidelines.

New or Replacement Line Set

Information on selecting and installing refrigerant line sets.

Brazing Connections

Safety and procedural guidance for making brazed refrigerant line connections.

Flushing Line Set and Indoor Coil

Steps for flushing the system to remove contaminants.

Leak Test Line Set and Indoor Coil

Method for testing the system for refrigerant leaks.

Evacuating Line Set and Indoor Coil

Steps to properly evacuate the refrigerant lines and indoor coil.

System Operation and Service

System Operation

Description of how the unit functions in cooling and heating modes.

Defrost System

Explanation of the defrost control and operation.

Maintenance Procedures

Recommended checks and cleaning for the outdoor and indoor units.

Start-Up and Performance Checklist

A form to verify all installation and startup steps are completed.

Sequence of Operations

Detailed step-by-step operational logic for the unit.

Servicing Units Void of Charge

Procedures for handling units that are empty of refrigerant.

System Start-Up

Steps to follow for the initial startup of the system.

System Refrigerant Handling

Procedures for connecting gauges, checking airflow, and handling refrigerant.

Adding or Removing Refrigerant

Instructions for adjusting the refrigerant charge in the system.

Weigh In Method

Method for calculating and adding the initial refrigerant charge.

Subcooling Method

Method for verifying the refrigerant charge using subcooling.

Related product manuals