© 1998 Lennox Industries Inc.
Corp. 9801−L2
80MGF
Service Literature
Revised 08−2004
80MGF SERIES UNITS
80MGF series units are mid−efficiency gas furnaces
manufactured with tubular heat exchangers formed of alu-
minized or stainless steel. 80MGF units are available in
heating capacities of 45,000 to 140,000 Btuh and cooling
applications up to 5 tons. Refer to Engineering Handbook
for proper sizing.
Units are factory equipped for use with natural gas. A kit is
available for conversion to LPG operation. All 80MGF units
built proir to September 98 use electronic (direct spark) igni-
tion. 80MGF−11 model units are equipped with the Lennox
SureLight ignition system. The 80MGFX unit meets the
California Nitrogen Oxides (NO
x
) Standards and California
Seasonal Efficiency requirements. All units use a redun-
dant gas valve to assure safety shut−off as required by
A.G.A. or C.G.A.
The heat exchanger, burners and manifold assembly can
easily be removed for inspection and service by simply dis-
connecting gas, unplugging wiring harness and spark wires
and removing four screws holding the heat exchanger in
place. Then the heat exchanger slides out of the cabinet.
All specifications in this manual are subject to change.
Procedures outlined in this manual are presented as a rec-
ommendation only and do not supersede or replace local
or state codes. In the absence of local or state codes, the
guidelines and procedures outlined in this manual (except
where noted) are recommended only and do not constitute
code.
Units may be installed in upflow, downflow or horizontal
position. The heat exchanger is designed for upright or
horizontal use only. When the unit is installed in the down-
flow position, the heat exchanger is field removed and re-
installed so it is upright when the cabinet is inverted. No
field conversion is required when the unit is installed in the
horizontal position.
TABLE OF CONTENTS
Introduction 1. . . . . . . . . . . . . . . . . . . . . . . .
Specifications 2. . . . . . . . . . . . . . . . . . . . . .
Blower Data 5. . . . . . . . . . . . . . . . . . . . . . .
Parts Identification 7. . . . . . . . . . . . . . . . . .
I Unit Components 9. . . . . . . . . . . . . . . . . .
II Installation 19. . . . . . . . . . . . . . . . . . . . . . .
III Start Up 19. . . . . . . . . . . . . . . . . . . . . . . . .
Preliminary Seasonal Checks 20 . . . . .
Heating Start Up 20. . . . . . . . . . . . . . . .
IV Heating System Service Checks 20. . .
V Typical Operating Characteristics 22. . .
VI Maintenance 24. . . . . . . . . . . . . . . . . . . .
VII Wiring and Sequence of Operation 26.
VIII SureLight Control Troubleshooting 40.
Question and Answer IconNeed help?

Do you have a question about the Lennox 80MGF3/4-100 and is the answer not in the manual?

Lennox 80MGF3/4-100 Specifications

General IconGeneral
BrandLennox
Model80MGF3/4-100
CategoryFurnace
LanguageEnglish

Summary

80 MGF PARTS IDENTIFICATION and ORIENTATION

I-UNIT COMPONENTS

A-Blower Door Components

Details about components located on the blower access door, including transformer and switches.

4- EGC Control (A3)

Troubleshooting

6- SureLight Ignition System A3 (-11 models)

III-START-UP

IV-HEATING SYSTEM SERVICE CHECKS

V-TYPICAL OPERATING CHARACTERISTICS

VI-MAINTENANCE

VII-WIRING AND SEQUENCE OF OPERATION

80 MGF WITH RAM CONTROL

Wiring diagram and step-by-step sequence of operation for furnaces equipped with the RAM control.

80 MGF TROUBLESHOOTING SEQUENCE

80 MGF TROUBLESHOOTING SEQUENCE - COOLING

80 MGF TROUBLESHOOTING SEQUENCE - FAN ONLY

SURELIGHT CONTROL HEATING SEQUENCE OF OPERATION

NORMAL HEATING MODE

Flowchart for normal heating operation with SureLight control, including self-checks and ignition sequence.

ABNORMAL HEATING MODE

Flowchart for abnormal heating operation with SureLight control, detailing fault conditions and LED codes.

SURELIGHT CONTROL COOLING SEQUENCE OF OPERATION

NORMAL COOLING MODE

Flowchart for normal cooling operation with SureLight control, detailing thermostat calls and system fan operation.

ABNORMAL COOLING MODE

Flowchart for abnormal cooling operation with SureLight control, outlining fault conditions and LED signals.

SURELIGHT CONTROL CONTINUOUS LOW SPEED FAN SEQUENCE OF OPERATION

Related product manuals