NOTE - When installing refrigerant lines longer than 15.2
meters, see the Lennox Refrigerant Piping Design and
Fabrication Guidelines, CORP. 9351-L9, or contact Len-
nox Technical Support Product Applications for assis-
tance. To obtain the correct information from Lennox, be
sure to communicate the following information: Model and
capacity.
1 - Route the suction and liquid lines from the ttings
on the indoor coil to the ttings on the outdoor unit.
Run the lines in a direct path, avoiding unnecessary
turns and bends.
2 - Make sure that the suction line is insulated over the
entire exposed length and that neither suction nor
liquid lines are in direct contact with oors, walls,
duct system, oor joists, or other piping.
3 - To avoid damaging the rubber grommets in the
cabinet while brazing, slide the rubber grommets
over the refrigerant lines until they are away from
the heat source.
NOTE - Place wet rags against piping plate and around
suction line connections.
4 - Connect the suction and liquid lines to the evaporator
coil. Take care to protect the cabinet and internal
components as detailed in gure 14.
5 - Braze using an alloy of silver or copper and
phosphorus with a melting point above 1,100°F
(593°C).
NOTE - Do not use soft solder.
6 - Allow refrigerant pipes to cool to room temperature.
NOTE - Make sure to route copper refrigerant tubing away
from sharp edges and make sure that it does not touch
other metal surfaces. This prevents damage caused by
vibration or metal-on-metal contact.
7 - Reinstall the rubber grommets into the refrigerant
piping panel.
NOTE - Make sure expansion valve capillary tube is not
touching metal edges or copper tubing.
8 - Make sure outdoor unit has been placed according
to the Installation Instructions and is connected to