Page 18
Instal-
lerSet−
Up No.
Notes
Selection Description
(Factory setting in bold print)
Installer
Set−Up
Name
0690
Cooling
Mode
Tempera-
ture Con-
trol
1 − Less aggressive control. (Cooling may
turn off before setpoint reached).
2 − Standard control. Factory setting.
3 − More aggressive control. (Cooling may
remain on after setpoint reached).
Applies to re-
covery ramp.
0700
Tempera-
ture Dis-
play Off-
set
−3°F (−1.5°C).
−2°F (−1°C).
−1°F (−.5°C).
0 − No difference in displayed tempera-
ture and actual room temperature. Fac-
tory setting.
1°F (.5°C).
2°F (1.5°C).
3°F (2°C).
0710
Reset
Thermo-
stat
0 − No thermostat reset. Factory setting.
1 − Resets all installer set−up options to
default values and resets schedule to
default setting.
Only calendar
settings and
time are re-
tained.