Equipment Available When SSR is enabled then SSR
Stage 2 lock out is automatically
enabled.
When SSR is disabled then
SSR Stg 2 lock-out setting is
disabled.
Single-stage heat pump with
single-stage gas or oil backup
Run heat pump (Y1) only
All backup heat (W1) is enabled
and SSR Stage 2 Lock Out is set
between 20 - 120 minutes before
the wake-up set point.
Run heat pump (Y1) until a
second stage heating demand is
needed which is determined by
the time / temperature di󰀨erential.
Heat pump operation will stop and
gas or oil heat will start.
Changeover and lock-in to W1
heat will occur until set point
reached.
Single-stage heat pump with:
Two-stages of gas or oil backup
Modulation furnace
Run heat pump (Y1) only
All backup heat (W1/W2) is
enabled and SSR Stage 2 Lock
Out is set between 20 - 120
minutes before the wakeup set
point.
Run heat pump (Y1) until a
second stage heating demand is
needed which is determined by
the time / temperature di󰀨erential.
Heat pump operation will stop and
changeover to W1/W2 heat as
needed
Lock-in W1/W2 heat until set point
is reached.
Two-stage heat pump with one
stage gas/oil backup
Run heat pump (Y1/Y2) only.
All backup heat (W1/W2) is
enabled and SSR Stage 2 Lock
Out is set between 20 - 120
minutes before the wakeup set
point.
Run heat pump (Y1/Y2) until a
second-stage demand is needed
which is determined by the time /
temperature di󰀨erential.
Heat pump operation will stop and
gas or oil heat will start.
Changeover and lock-in to W1
heat will occur until set point is
reached