Turn on power to unit. Check for 120 volts across terminals
“L” and “N” on input plug P48. If voltage is present continue
to test 2. If voltage is not present problem may be may be up
stream of plug P48 and proceed to test 3.
1
2
3
4
5
C
L
G
N
MultiMeter
(set to VAC)
P48
P49
24
Switch thermostat to CONTINUOUS FAN MODE. Check for
24 volts across terminalC” on input plug P48and speed tap
used for continuous fan. (1, 2, 3, 4 or 5) on input plug P49. If
24 volts is not present problem may be up stream of plug P49.
Proceed to test 4.
MultiMeter
(set to VAC)
12
0
12
0
24
MultiMeter
(set to VAC)
Check for 24 volts across terminals “24 COM” and the “ac
tive speed tap” on the integrated control. If voltage is pres
ent, problem is with the harness. If voltage is not present
problem may be may be with the integrated control
Check for 120 volts across terminals “L1” andNeutrals” on
the integrated control. If voltage is present, problem is with
the harness. If voltage is not present problem may be may
be with the integrated control.
Test 1
Test 2
Test 3 (if necessary)
Test 4 (if necessary)
FIGURE 8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox EL280DF070E36A and is the answer not in the manual?

Lennox EL280DF070E36A Specifications

General IconGeneral
BrandLennox
ModelEL280DF070E36A
CategoryHeat Pump
LanguageEnglish

Related product manuals