Page 83
Ignition Control 103130-XX DIP Switch Settings and On Board Links
Thermostat
Wiring Connections
DIP Switch 1
Thermostat
Heating
Stages
On Board Links Must Be Cut To Select
System Options
Dual Fuel
Single Stage
Heat Pump
ComfortSense
thermostat w/
bilities
Capable of 2
stage gas heat
control
OFF
CUT ON-BOARD LINK
W951
HEAT
PUMP
T'STAT
FURNACE
TERM. STRIP
HEAT PUMP
67M41*
Y
H
L
Y2
D
B
L
Y2
T
T
outdoor
sensor
Dual Fuel
Two Stage
Heat Pump
ComfortSense
thermostat w/
bilities
Capable of 2
stage gas heat
control
OFF
CUT ON-BOARD LINK
W951
HEAT
PUMP
CUT ON-BOARD LINK
W915
2 STAGE
COMPR
FURNACE
TERM. STRIP
HEAT PUMP
out blue
67M41*
H
L
Y2
D
B
L
Y2
T
T
outdoor
sensor
T'STAT
* Connect W1 to W1 ONLY if using defrost tempering kit 67M41
NOTE - Do NOT make a wire connection between the room thermostat L terminal and the L terminal of the furnace

Other manuals for Lennox EL297DFV Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox EL297DFV Series and is the answer not in the manual?

Lennox EL297DFV Series Specifications

General IconGeneral
BrandLennox
ModelEL297DFV Series
CategoryFurnace
LanguageEnglish

Related product manuals