6 - Inspect contactor contacts for pitting or burn marks.
Replace as necessary.
7 - Check outdoor fan motor for worn bearings/
bushings. Replace as necessary.
8 - Inspect and clean outdoor coils, if necessary and
note any damage to coils or signs of leakage.
Indoor Unit (Air Handler or Furnace)
1 - Inspect component wiring for loose, worn or
damaged connections. Conrm proper voltage plus
amperage of indoor unit.
2 - Inspect and clean or replace air lters in indoor unit.
3 - Check the cleanliness of indoor blower and clean
blower, if necessary.
4 - Inspect the indoor coil drain pans and condensate
drains for rust, debris, obstructions, leaks or cracks.
Pour water in pans to conrm proper drainage from
the pan through to the outlet of the pipe. Clean or
replace as necessary.
5 - Inspect and clean indoor coil, if necessary.
6 - Inspect the condition of the refrigerant lines and
conrm that pipes are not rubbing copper-to-
copper. Also, ensure that refrigerant pipes are not
being a󰀨ected by indoor air contamination. Check
condition of insulation on the refrigerant lines.
Repair, correct, or replace as necessary.
7 - Inspect the duct system for leaks or other problems.
Repair or replace as necessary.
8 - Check for bearing/bushing wear on indoor blower
motor. Replace as necessary.
9 - If your heat pump is matched with a gas- or oil-red
furnace for auxiliary heating, indoor unit service
will also include inspection and cleaning of the
burners, and a full inspection of the gas valve, heat
exchanger and ue (exhaust) system.
General System Test with System Operating
1 - Your technician should perform a general system
test. He will turn on the air conditioner to check
operating functions such as the startup and shuto󰀨
operation. He will also check for unusual noises or
odors, and measure indoor/outdoor temperatures
and system pressures as needed. He will check
the refrigerant charge per the charging sticker
information on the outdoor unit.
2 - Verify that system total static pressure and airow
settings are within specic operating parameters.
3 - Verify correct temperature drop across indoor coil.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox Elite EL18XCV Series and is the answer not in the manual?

Lennox Elite EL18XCV Series Specifications

General IconGeneral
RefrigerantR-410A
Energy Star CertifiedYes
Climate ZonesSuitable for all climate zones
Cooling Capacity1.5 to 5 tons
Warranty10-Year Limited Warranty on covered components

Related product manuals