XC16 - 2 to 5 Ton Air Conditioner / Page 11
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC16-024-230 TXV 24,600 13.70 11.50 CX34-36 3068764
XC16-024-230 TXV 26,600 16.70 13.20 CX34-38 G61MPV-36B-045 3068804
XC16-024-230 TXV 26,400 17.00 13.20 CX34-38 G61MPV-36B-070 3068805
XC16-024-230 TXV 26,600 17.00 13.20 CX34-38 G61MPV-36B-071 3068807
XC16-024-230 TXV 26,400 17.20 13.50 CX34-38 SL280UH070V36A 3932966
XC16-024-230 TXV 26,400 17.20 13.50 CX34-38 SL280UH070XV36A 4037920
XC16-024-230 TXV 26,200 16.50 13.50 CX34-38 SL280UH090V36B 3932967
XC16-024-230 TXV 26,200 16.50 13.20 CX34-38 SL280UH090V48B 4249271
XC16-024-230 TXV 26,400 16.70 13.50 CX34-38 SLP98UH070V36B 4020634
XC16-024-230 TXV 25,400 14.20 11.70 CX34-38 3068765
XC16-036-230 TXV 34,400 15.50 11.20 C33-36 CBWMV-36C-090 3184066
XC16-036-230 TXV 34,200 15.20 11.00 C33-36 G61MPV-36B-045 3069107
XC16-036-230 TXV 34,400 15.50 11.00 C33-36 G61MPV-36B-070 3069108
XC16-036-230 TXV 34,200 15.20 11.00 C33-36 G61MPV-36B-071 3069110
XC16-036-230 TXV 34,200 15.50 11.50 C33-36 G61MPV-36C-090 3069111
XC16-036-230 TXV 34,200 15.50 11.20 C33-36 SL280UH070V36A 3932968
XC16-036-230 TXV 34,200 15.50 11.20 C33-36 SL280UH070XV36A 4037922
XC16-036-230 TXV 34,400 15.70 11.50 C33-36 SL280UH090V36B 3932969
XC16-036-230 TXV 34,400 15.50 11.50 C33-36 SL280UH090V48B 3932970
XC16-036-230 TXV 34,800 15.70 11.70 C33-36 SL280UH090V60C 3932971
XC16-036-230 TXV 34,400 15.50 11.50 C33-36 SL280UH090XV48B 4038663
XC16-036-230 TXV 34,800 15.70 11.70 C33-36 SL280UH090XV60C 4235446
XC16-036-230 TXV 34,600 15.70 11.50 C33-36 SL280UH110V60C 3932972
XC16-036-230 TXV 34,600 15.70 11.50 C33-36 SL280UH110XV60C 4040506
XC16-036-230 TXV 33,800 13.70 10.70 C33-36 3069097
XC16-036-230 TXV 35,600 16.00 11.20 C33-38 G61MPV-36B-045 3069115
XC16-036-230 TXV 35,400 16.00 11.50 C33-38 G61MPV-36B-070 3069116
XC16-036-230 TXV 35,400 16.00 11.50 C33-38 G61MPV-36B-071 3069118
XC16-036-230 TXV 35,600 16.00 11.50 C33-38 SL280UH070V36A 3932973
XC16-036-230 TXV 35,600 16.00 11.50 C33-38 SL280UH070XV36A 4037923
XC16-036-230 TXV 35,800 16.20 11.70 C33-38 SL280UH090V36B 3932974
XC16-036-230 TXV 35,800 16.00 12.00 C33-38 SL280UH090V48B 3932975
XC16-036-230 TXV 35,800 16.00 12.00 C33-38 SL280UH090XV48B 4038664
XC16-036-230 TXV 34,600 14.00 10.90 C33-38 3069098
XC16-036-230 TXV 34,200 15.20 11.00 C33-42 G61MPV-36B-045 3069120
XC16-036-230 TXV 34,000 15.20 11.00 C33-42 G61MPV-36B-070 3069121
XC16-036-230 TXV 34,000 15.20 11.00 C33-42 G61MPV-36B-071 3069123
XC16-036-230 TXV 34,400 15.70 11.50 C33-42 SL280UH090V36B 3932976
XC16-036-230 TXV 34,400 15.50 11.50 C33-42 SL280UH090V48B 3932977
XC16-036-230 TXV 34,400 15.50 11.50 C33-42 SL280UH090XV48B 4038665
XC16-036-230 TXV 33,800 13.70 10.70 C33-42 3069099
XC16-036-230 TXV 35,800 16.00 11.70 C33-43 CBWMV-36C-090 3184068
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.