Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC16-036-230 TXV 35,600 16.00 11.50 C33-43 G61MPV-36B-045 3069126
XC16-036-230 TXV 35,400 16.00 11.50 C33-43 G61MPV-36B-070 3069127
XC16-036-230 TXV 35,400 16.20 12.00 C33-43 G61MPV-36C-090 3069129
XC16-036-230 TXV 36,200 16.20 12.00 C33-43 G61MPV-60C-090 3069131
XC16-036-230 TXV 36,200 16.20 11.70 C33-43 G61MPV-60C-091 3069133
XC16-036-230 TXV 36,200 16.00 12.00 C33-43 G61MPV-60C-110 3069134
XC16-036-230 TXV 36,200 16.20 12.00 C33-43 G61MPV-60C-111 3069136
XC16-036-230 TXV 36,000 16.20 11.70 C33-43 SL280UH090V36B 3932978
XC16-036-230 TXV 35,800 16.00 12.00 C33-43 SL280UH090V48B 3932979
XC16-036-230 TXV 36,400 16.50 12.00 C33-43 SL280UH090V60C 3932980
XC16-036-230 TXV 35,800 16.00 12.00 C33-43 SL280UH090XV48B 4038666
XC16-036-230 TXV 36,400 16.50 12.00 C33-43 SL280UH090XV60C 4235447
XC16-036-230 TXV 36,000 16.20 12.00 C33-43 SL280UH110V60C 3932981
XC16-036-230 TXV 36,000 16.20 12.00 C33-43 SL280UH110XV60C 4040507
XC16-036-230 TXV 35,200 14.20 11.00 C33-43 3069100
XC16-036-230 TXV 35,200 16.00 11.70 C33-44C G61MPV-36C-090 3068698
XC16-036-230 TXV 35,600 16.20 11.70 C33-44C G61MPV-60C-090 3068700
XC16-036-230 TXV 35,800 16.00 11.50 C33-44C G61MPV-60C-091 3068702
XC16-036-230 TXV 35,600 15.70 11.70 C33-44C G61MPV-60C-110 3068703
XC16-036-230 TXV 35,600 16.20 11.70 C33-44C G61MPV-60C-111 3068705
XC16-036-230 TXV 35,200 15.70 11.20 C33-48 G61MPV-36B-045 3069140
XC16-036-230 TXV 35,000 15.70 11.50 C33-48 G61MPV-36B-070 3069141
XC16-036-230 TXV 35,200 15.70 11.20 C33-48 G61MPV-36B-071 3069143
XC16-036-230 TXV 35,200 16.00 11.70 C33-48 G61MPV-36C-090 3069144
XC16-036-230 TXV 35,600 16.00 11.70 C33-48 G61MPV-60C-090 3069146
XC16-036-230 TXV 35,800 16.00 11.50 C33-48 G61MPV-60C-091 3069148
XC16-036-230 TXV 35,600 15.70 11.70 C33-48 G61MPV-60C-110 3069149
XC16-036-230 TXV 35,600 16.00 11.70 C33-48 G61MPV-60C-111 3069151
XC16-036-230 TXV 35,400 16.00 11.70 C33-48 SL280UH090V36B 3932982
XC16-036-230 TXV 35,400 15.70 11.70 C33-48 SL280UH090V48B 3932983
XC16-036-230 TXV 35,800 16.20 11.70 C33-48 SL280UH090V60C 3932984
XC16-036-230 TXV 35,400 15.70 11.70 C33-48 SL280UH090XV48B 4038667
XC16-036-230 TXV 35,800 16.20 11.70 C33-48 SL280UH090XV60C 4235448
XC16-036-230 TXV 35,600 16.00 11.70 C33-48 SL280UH110V60C 3932985
XC16-036-230 TXV 35,600 16.00 11.70 C33-48 SL280UH110XV60C 4040508
XC16-036-230 TXV 34,800 14.20 10.90 C33-48 3069101
XC16-036-230 TXV 36,600 16.70 12.20 C33-49 SL280UH090V60C 3932986
XC16-036-230 TXV 36,600 16.70 12.20 C33-49 SL280UH090XV60C 4235449
XC16-036-230 TXV 36,400 16.20 12.00 C33-49 SL280UH110V60C 3932987
XC16-036-230 TXV 36,400 16.20 12.00 C33-49 SL280UH110XV60C 4040509
XC16-036-230 TXV 35,600 14.50 11.00 C33-49 3069102
XC16-036-230 TXV 34,800 14.70 11.20 CB26UH-030 3069152
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.