XC16 - 2 to 5 Ton Air Conditioner / Page 13
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC16-036-230 TXV 35,200 14.70 11.20 CB26UH-036 3069153
XC16-036-230 TXV 34,800 14.70 11.20 CBX26UH-030 3068746
XC16-036-230 TXV 35,200 14.70 11.20 CBX26UH-036 3068747
XC16-036-230 TXV 35,000 15.70 11.70 CBX27UH-036 3068754
XC16-036-230 TXV 36,000 16.50 12.00 CBX27UH-042 3068755
XC16-036-230 TXV 34,200 15.00 11.00 CBX32M-030 3068748
XC16-036-230 TXV 34,400 14.70 11.00 CBX32M-036 3068749
XC16-036-230 TXV 34,600 14.70 11.20 CBX32M-042 3068750
XC16-036-230 TXV 34,400 15.50 11.20 CBX32MV-024/030 3068751
XC16-036-230 TXV 35,000 16.00 11.50 CBX32MV-036 3068752
XC16-036-230 TXV 36,000 16.50 12.00 CBX32MV-048 3068753
XC16-036-230 TXV 34,400 15.50 11.20 CBX40UHV-030 3291635
XC16-036-230 TXV 35,000 16.00 11.50 CBX40UHV-036 3291687
XC16-036-230 TXV 36,000 16.50 12.00 CBX40UHV-042 3291711
XC16-036-230 TXV 36,000 16.50 12.00 CBX40UHV-048 3291797
XC16-036-230 TXV 34,400 15.50 11.50 CH23-41 G61MPV-36B-070 3068714
XC16-036-230 TXV 34,600 16.00 11.70 CH23-41 SL280UH090V36B 3932988
XC16-036-230 TXV 34,800 15.70 11.70 CH23-41 SL280UH090V48B 3932989
XC16-036-230 TXV 35,400 16.20 12.00 CH23-41 SL280UH090V60C 3932990
XC16-036-230 TXV 34,800 15.70 11.70 CH23-41 SL280UH090XV48B 4038668
XC16-036-230 TXV 35,400 16.20 12.00 CH23-41 SL280UH090XV60C 4235450
XC16-036-230 TXV 35,000 16.00 11.70 CH23-41 SL280UH110V60C 3932991
XC16-036-230 TXV 35,000 16.00 11.70 CH23-41 SL280UH110XV60C 4040510
XC16-036-230 TXV 34,800 15.70 11.50 CH23-41 SLP98UH070V36B 4020635
XC16-036-230 TXV 34,800 16.00 11.70 CH23-41 SLP98UH090V36C 4020636
XC16-036-230 TXV 34,600 16.00 11.70 CH23-41 SLP98UH090V48C 4020637
XC16-036-230 TXV 35,400 16.20 11.70 CH23-41 SLP98UH090V60C 4020638
XC16-036-230 TXV 35,200 16.00 11.70 CH23-41 SLP98UH110V60C 4020639
XC16-036-230 TXV 34,200 13.70 10.80 CH23-41 3068640
XC16-036-230 TXV 35,800 16.50 12.00 CH23-65 SL280UH090V60C 3932992
XC16-036-230 TXV 35,800 16.50 12.00 CH23-65 SL280UH090XV60C 4235445
XC16-036-230 TXV 35,600 16.20 12.00 CH23-65 SL280UH110V60C 3932993
XC16-036-230 TXV 35,600 16.20 12.00 CH23-65 SL280UH110XV60C 4040505
XC16-036-230 TXV 35,400 16.20 11.70 CH23-65 SLP98UH090V36C 4020640
XC16-036-230 TXV 35,200 16.20 12.00 CH23-65 SLP98UH090V48C 4020641
XC16-036-230 TXV 35,800 16.20 11.70 CH23-65 SLP98UH090V60C 4020642
XC16-036-230 TXV 35,600 16.20 12.00 CH23-65 SLP98UH110V60C 4020643
XC16-036-230 TXV 34,600 14.00 10.90 CH23-65 3068641
XC16-036-230 TXV 34,000 15.20 11.00 CH33-36 SL280UH070V36A 3932994
XC16-036-230 TXV 34,000 15.20 11.00 CH33-36 SL280UH070XV36A 4037921
XC16-036-230 TXV 34,400 15.70 11.50 CH33-36 SL280UH090V36B 3932995
XC16-036-230 TXV 34,200 15.50 11.50 CH33-36 SL280UH090V48B 3932996
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.